GE PSB2201NSS Manual De Usuario

Descargar
Página de 3
Specification Created 9/08
240441
Listed by 
Underwriters 
Laboratories
PSB2201NSS 
GE Profile Advantium
® 
240 Wall Oven
 
For answers to your Monogram,
® 
GE Profile
 or  
GE
®
 appliance questions, visit our website at 
ge.com or call GE Answer Center
®
 service,  
800.626.2000.
cooking_tower_solid_floor.eps
CL
(Must support 130 lbs.)
2 x 4’s or
equivalent
solid floor
Suitable
bracing
to support
runners
21-5/8"
over centerline
of cabinet
A=Allow 1" overlap of oven over top and bottom edges of cutout.
B=Allow 11/16"-3/4" for overlap ov oven over side edges of cutout.
Cabinet 
Width
(inches)
Width
Height
D
Depth
(excluding
handle)
Cutout 
Width
Cutout 
Height
Cutout 
Depth
(minimum)
PSB2200/1 without 
accessory drawer
30
29-25/32
19-1/8
21-3/4
25-1/8
17-1/2
23-1/2
PSB2200/1 with  
accessory drawer
30
29-25/32
22-1/4
21-3/4
25-1/8 to 
28-1/2*
21
23-1/2
*For existing cutouts a maximum width of 28-1/2" is acceptable
A=Allow 1" overlap of oven over top and bottom edges of cutout.
B=Allow 11/16"-3/4" for overlap ov oven over side edges of cutout.
Note: Cabinets 
installed adjacent 
to wall ovens must  
have an adhesion  
spec of at least a  
194°F temperature  
rating. 
Note: 2" minimum  
between cutouts 
when installed 
above warming  
drawer or single  
wall oven. 
Installation 
Information:  
Before installing,  
consult  installation 
instructions packed 
with product for  current 
dimensional data.
Cutout width
25-1/8" 
30
Required
cutout location
36-3/4" 
minimum
from floor
Junction 
box
location
(240-Volt 
models only)
A=Allow 1" overlap of oven over top and bottom 
edges of cutout.
B=Allow 11/16"-3/4" for overlap ov oven over side 
edges of cutout.
4-3/16
17-1/2"
Cutout height
A
B
23-1/2"
Cutout depth
29-25/32"
19-1/32"
21-1/2"
Excluding
Handle
Advantium Wall Oven Dimensions (in inches)and 
Cabinet Installation (in inches)
Note: Cabinets installed adjacent 
to wall ovens must have an adhesion 
spec of at least 194° F temperature rating.
Construct Solid
Bottom Min. 
3/8" Plywood
Supported by
2 x 4 or 1 x 2
Runners, all 
Four Sides.
(Must Support
150 lbs.)
Conduit
(48-1/2" 
long)
adv_240_120_cooktower_dia.eps
1" Min. above toekick or adjust 
to oven installation height
2" MIN between cutouts
2-1/2" MIN between cutouts 
recommended—2" MIN required
9-1/4" cutout height
28-1/2" cutout width
Junction box location
A
B
A
B
Construct Solid Bottom 
MIN 3/8" Plywood Supported by
2 x 4 or 1 x 2 Runners, all Four Sides.
(Must Support 150 lbs. for Advantium)
(Must Support 200 lbs. for Wall Oven)
4-3/16
D
Excluding
Handle
H
W
Conduit
(46" long)
Cabinet width
(240-volt models only)