Component Testing Information 
 
!
WARNING
 
To avoid risk of electrical shook, personal injury or death: disconnect power to oven before servicing, unless  
testing requires it. 
 
 
16021875   Rev. 0 
©2003 Maytag Appliances Company
 
10 
 
Illustration Component 
Test 
Procedure 
Results 
 
 
Oven light socket 
Test continuity of receptacle terminals. 
 
Measure voltage at oven light. 
Indicates continuity with bulb screwed in. 
 
120 VAC, see wiring diagram for terminal 
identification. 
If no voltage is present at oven light 
check wiring. 
 
 
Bake element 
Test continuity of terminals. 
 
Test voltage to terminals. 
Indicates continuity. 
 
240 VAC 
 
 
Broil element 
Test continuity of terminals. 
 
Test voltage to terminals. 
Indicates continuity. 
 
240 VAC 
 
 
Convection element 
Test continuity of terminals. 
 
Test voltage to terminals. 
Indicates continuity. 
 
240 VAC 
 
 
Convection motor fan 
Verify supply voltage. 
Check continuity of terminals, and 
verify terminals are not shorted to 
chassis. 
120 VAC 
Continuity 
 
Convection fan will stay ON, when 
oven door is opened.
 
 
 
 
Blower motor 
Verify supply voltage. 
Check continuity of terminals, and 
verify terminals are not shorted to 
chassis. 
120 VAC 
Continuity 
 
 
Heraeus sensor 
Measure resistance. 
 
Approximately 1100 
Ω
 at room 
temperature 75
º
F. 
 
 
Opening
 
Hinge 
Carefully open the hinge fully, and 
insert a wooden dowel or screwdriver 
bit into opening. 
Remove top and bottom screws 
securing hinge. 
Slide hinge top towards rear of unit 
and guide hinge out through frame 
opening or storage drawer. 
 
CAUTION
!
 
Do not place hands in hinge area when 
oven door is removed. Hinge can snap 
closed and pinch hands or fingers. 
 
COM
NC
NO
 
Door lock switch 
Switch connection in following 
positions: 
Unlocked 
Locked 
 
COM-NO=Open, COM-NC=Closed 
COM-NO=Closed, COM-NC=Open 
 
 
Controls 
Verify proper operation. 
31–308417–02–0  Fan control 
31–31751801–0  Control limit 
 
 
Open at 115°F, Closes at 155°F 
Open at 260°F, Closes at 220°F 
 
NC
NO
C
 
Door plunger switch 
Remove switch from unit and measure 
the following points: 
C-NC 
C NO 
 
 
Plunger in infinite, Plunger out continuity. 
Plunger in continuity, Plunger out infinite.