Garland MPOE5L Manual De Usuario

Descargar
Página de 16
Part # 4518084 Rev. 1 (09/04)
Page 13
Temperature does not correspond to the pyrometer, 
enter the value on the pyrometer using buttons 1 
– 0. The value will be input as Set Temp.
 
3.  Press “ENTER” (lower right blank) to accept the 
changes.  The  Actual  Temperature  will  change  to 
equal  the  value  input  for  Set  Temperature.  Press 
Cancel to exit Temperature Calibration. 
•  After  the  desired  Tests  are  complete,  press 
“CANCEL” to exit Diagnostics Mode.
Control Safety Features
The control has several built in safety features to protect 
both the user and the oven itself.
•  If the actual temperature inside the oven exceeds 
the set temperature by 50°F, the display will show 
“HI TEMP” and the alarm will sound. The fan will 
continue to run, however, power to the heaters will 
be cut. 
 
•  If the actual temperature sensed inside the oven 
exceeds 575°F, the control will change to “HELP” 
and the alarm will sound continuously. All control 
operations will shut down except the alarm. 
 
  • NOTE
: The control will need a complete power 
down  and  restart  (unplug/plug  in  oven)  before 
any control functions will become operational. If 
the problem persists, contact a service technician.
OPERATING INSTRUCTIONS continued...
•  In  the  event  of  a  temperature  probe  failure,  the 
control  will  become  inoperative  and  the  display 
will show “PROBE ERROR”. Once the problem 
is  corrected,  the  control  must  be  cycled  On/Off 
(using the ON/OFF button) in order to become 
operative again.
 
Installing a New Pecipe Program
Using the CARD Reader
1.  Remove  the  two  screws  securing  the  controller 
button pad to the front panel using a Phillips head 
screw driver, and drop the button pad to access the 
CARD reader.
2.  Press  and  hold  the  programming 
button (bottom right button), until the 
controller display reads “enter code”.
3.  Insert  the  CARD  into  the  reader  with 
gold side up.
4.  The LED on the reader will illuminate 
yellow for five seconds then red during the coding.
5.  When the LED changes color to green, remove the 
card.
6.  Program is complete. Close the panel and exit the 
program mode by hitting the cancel button.
7.  Power down the oven and re-start.