Southbend SSB-32 Manual De Usuario

Descargar
Página de 20
R
ADIANT 
S
TEAKHOUSE 
B
ROILER
 
S
PECIFICATIONS
 
O
WNER
M
ANUAL 
1190950
 
(02/09) P
AGE 
5
 OF 
20 
D
IMENSIONS
 
 
 
 
Figure 2
    
 
FRONT VIEW
RIGHT SIDE VIEW
A
57.0"
(1448)
Dimensions in Inches (Millimeters)
Minimum Clearances 6" (152) Rear and Sides
Floor to
Griddle Surface
52.5" (1334)
Floor to
Broiler Surface
(Lowest Position)
41.0" (1041)
38.75" (984)
41.5" (1054)
 
 
 
Total BTU’s 
 
 
Model Number 
Width “A” 
Number 
Burners 
Nat Gas 
Propane 
Crated Weight 
 
 
SSB-32 
32" (813 mm) 
84,000 
73,000 
428 lbs (195 kg) 
 
 
SSB-36 
36" (914 mm) 
84,000 
73,000 
512 lbs (232 kg) 
 
 
SSB-45 
45" (1143 mm) 
126,000 
109,500 
616 lbs (279 kg) 
 
 
 
 
 
 
 
 
 
 
V
ENTILATION
 
 WARNING 
Improper ventilation can result in personal injury or death. Ventilation, which fails to properly remove flue products, 
can cause headaches, drowsiness, nausea, or could result in death. 
The flue vent, located at the top rear of the unit, must not be blocked or covered at any time. 
All gas appliances must be installed in such a manner that the flow of combustion and ventilation air is not 
obstructed. Provisions for adequate air supply must be provided. 
 
NOTICE 
Proper ventilation is the owner’s responsibility. Any problem due to improper ventilation will not be covered by the 
warranty. 
Do not obstruct the rear of the broiler since combustion air enters through this area. Be sure to inspect and clean 
the ventilation system according to the ventilation equipment manufacturer’s instructions.