GE PT925SNSS Manual De Usuario

Descargar
Página de 3
Listed by 
Underwriters 
Laboratories
For answers to your Monogram,
® 
GE Profile
 or  
GE
®
 appliance questions, visit our website at 
ge.com or call GE Answer Center
®
 service, 
800.626.2000.
Dimension and installation information are shown in inches.
Specification Revised 4/09
220245
PT925SN 
GE Profile
 30" Built-In Single/Double Convection Wall Oven
 
KW Rating
240V
3.9
208V 2.9
Breaker Size
240V
20 Amps
208V 20 Amps
Most 30” Wall Cabinets can be used with this unit.
Note:
 These ovens are not approved for 
stackable installations. Cabinets installed 
adjacent to wall ovens must have an adhesion 
spec of at least a 194°F temperature rating.
Door handle protrudes 3" from door face. Cabinets 
and drawers on adjacent 45° and 90° walls should 
be placed to avoid interference with the handle.
Electric wall ovens are not approved for 
installation with a plug and receptacle. They 
must be hard wired in accordance with  
installation instructions
Installation Information: Before installing, consult 
installation instructions packed with product for 
 current dimensional data.
Side-by-side installations require at least 2" 
between cutouts.
CUTOUT
HEIGHT
27 1/4" MIN.
27 5/16" MAX.
CUTOUT
WIDTH
28 1/2" MIN.
28 5/8" MAX.
5"
22" TO
BOTTOM OF 
JUNCTION BOX
JUNCTION B
LOCATION
RECOMMENDED
CUTOUT
LOCATION
32 1/2"
FROM THE 
FLOOR
CABINET
WIDTH
30"
ALLOW 11/16" FOR
OVERLAP OF THE 
OVEN OVER SIDE
EDGES OF CUTOUT
THE OPENING 
BETWEEN INSIDE
 WALLS MUST
BE AT LEAST 
28 1/2"WIDE
ALLOW 1" FOR 
OVERLAP
ON OVEN TOP 
AND BOTTOM 
OF CUTOUT
21"
ALLOW A MINIMUM
F 21" FOR CLEARANCE 
ADJACENT CORNERS, 
RAWERS, WALLS ETC. 
N THE DOOR IS OPENED.
Allow 11/16 
(1.75 cm)  for 
overlap of oven 
over side edges 
of cutout
Cutout
Width
28 1/2” 
(72.4 cm)
Min.
28 5/8” 
(72.7 cm)
Max.
15
(38.1 cm) 
Cabinet
Width
30
(76.2 cm) 
Allow a minimum 
of 15” (38.1 cm) for 
clearance to adjacent 
corners, drawers, 
walls, etc. when 
door is open
Allow 1” (2.5 cm) 
minimum for 
overlap of oven 
top and 1 1/4” 
(3.2 cm) overlap 
of oven bottom 
of cutout
Recommended 
cutout 
location from 
floor 26 1/2” 
(67.3 cm) max
Opening 
Between 
Inside Walls 
Must Be 
At Least 
28 1/2” 
(72.4 cm) 
Wide
Junction Box 
Location
(junction box 
may be 
located in 
adjacent 
cabinet)
9 1/2” 
(12.7 cm)
Max.
Cutout
Height
27 1/4 
(69.2 cm) Min. 
27 5/16 
(69.4 cm) Max.
22 (55.9 cm) 
Min. to
Bottom of 
Junction Box
CL
2 x 4 or
equivalent
runners
Suitable
bracing
to support
runners
21-5/8"
over centerline
of cabinet
(must support 275 lbs.)
Cutout width
28-1/2'' MIN.
28-5/8'' MAX.
29-3/4
C
30
Recommended 
cutout location 
32-1/2" 
from floor
21
Junction 
box
location
Allow minimum of 21'' for clearance
to adjacent corners, drawers, walls, or etc.
A=Allow 1" overlap of oven over top and bottom edges of cutout.
B=Allow 11/16"–3/4" for overlap of oven over side edges of cutout.
C=28-1/4" without trim and 28-3/4" with trim.
Conduit
(72" 
long)
5
27-1/4'' MIN.
27-5/16'' MAX.
Cutout height
A
B
23-1/2'' MIN.
Cutout depth
22'' MIN.
Dimensions and Installation Information (in inches)