34×24 BB GAS
As continuous product improvement occurs, specifications may be changed without notice.
DESCRIPTION
The Keating Instant Recovery
®
34×24 BB Fryer consists of a frying
vessel 34"×24” having a splash deck and a splash back installed in
a cabinet equipped with gas burners and an automatic temperature
control mechanism, all arranged and designed for the proper frying
of food.
SPECIFICATIONS
Frying Vessel: 
shall be constructed from 18 gauge stainless
steel, shall have a shortening capacity of 195 pounds, shall be
equipped with six 18 gauge horizontal heat transfer tubes
spaced above the bottom of the vessel so that the bottom is
unheated and the food particles collecting in this bottom zone
are unheated and therefore do not carbonize. The frying vessel
shall be polished to inhibit carbon build-up and facilitate easy
clean-up.
The heat transfer tubes shall be 3" wide and 5" high. The
bottom of the vessel shall slope toward the front where it shall be
equipped with two 1
1
/
4
" Teflon core 
1
/
4
turn, drain valve, so arranged
that the shortening can be drained into a receiving vessel placed in
front of the fryer.
Splashdeck shall slope toward the shortening containing vessel.
The splash deck  shall be made of 16 gauge 304 stainless steel.
Splashback 
shall be made of 18 gauge 304 stainless steel, shall
completely cover the sides of the flue.
Cabinet: 
shall be made of 18 gauge stainless steel. The cabinet
shall be rigid in construction and shall have four 8"
adjustable legs. Two doors made of 22 gauge 304 stainless
steel
shall cover the front of the cabinet and shall extend from the
bottom of the fryer to the panel, and above the panel shall be a
canopy. Each door shall be one-half of the width of the cabinet.
No additional space is required for the door to open a full 90
degrees. A stainless steel flue deflector is provided for installing
onto the flue back.
Heat Transfer Tubes
to be six, made of stainless steel polished
to a #7 mirror finish. 
Thermostat shall be close range, hydraulic type and be accurate
to ±3°F from 300° to 375°F with stainless steel bulb. Application
of this thermostat is patented by Keating.
Hi-Limit Control shall be manually resettable type with stainless
steel bulb.
100% Safety Shut Off shall be flame switch type with dual
combination control gas valve.
Melt Cycle shall be standard on “BB” fryers, allowing the safe
melting of solid shortening. Fryer is to be left in the Melt Cycle
mode until oil completely covers heat transfer tubes.
Indicating Lights & Switches. Power on switch, power on light,
pilot switch, pilot on light, fry off melt switch.
Standard Accessories to include one pair split size 4 mesh
baskets, one triple size 4 mesh basket, grid screen over heat
transfer tubes, drain clean out rod and sample of Keating Klenzer
and Sea Powder.
Electrical Connections to be 120V 1 amp, supplied with cord
and 3 pronged plug.
Gas Requirements to install are 
3
/
4
" male NPT connection and 4"
water column pressures natural and 10" for LP gas at the fryer
burner manifold. Supply pressure to fryers must be 7” (natural gas)
and 11” (LP) water column.
Special Order Options may include battery, common manifold,
rear drain, casters, cover, thermostat seals, portable filter, central
filter (CF34×24SE), Safe & Easy filter, security package, spark
ignition.
INST
ANT RECO
VER
Y
®
FR
YER 
34×24 BB GAS
Printed in U.S.A. 
34x24BBg2007
7/07
Oil
BTU
Ship
Model No. and Description
Capacity
Input
Height
Depth
Width
Wt.
34x24 BB Nat Gas
195 lbs.
201,000
46
1
/
2
"
42
1
/
2
"
35
3
/
8
"
435 lbs.
34x24 BB LP Gas
195 lbs.
198,000
46
1
/
2
"
42
1
/
2
"
35
3
/
8
"
435 lbs.
34×24 Safe & Easy
-
-
46
1
/
2
"
42
5
/
8
"
35
3
/
8
"
-
KEATING OF CHICAGO, INC.
1-800-KEATING
www.keatingofchicago.com
300
27
5
A L
OT C
2
5
0
35
0
D
T
R A
I B
T
HS
E
I F
I A L
3
7
5
325
MELT - FRY
POWER POWER 
ON
PILOT 
ON
PILOT
GAS INLET
WITH NEMA 5-15 PLUG
6 FT. 3-WIRE CORD
FRYER POWER
GAS IN
3/4" NPT
12 1/2
8
42 1/2
46 1/2
35
38
9 5/8
35 3/8