default local disk configuration policy from a B200M1 or M2 server to a B200 M3 server. The default local
disk configuration policy includes those with Any Configuration or JBOD configuration.
JBOD Mode Support
Only B200 M1, B200 M2, B200 M3, B250 M1, B250 M2 and B22 M3 blade servers support the JBOD
mode for local disks.
Note
Guidelines for Local Disk Configuration Policies Configured for RAID
Configure RAID Settings in Local Disk Configuration Policy for Servers with MegaRAID Storage Controllers
If a blade server or integrated rack-mount server has a MegaRAID controller, you must configure RAID
settings for the drives in the Local Disk Configuration policy included in the service profile for that server.
You can do this either by configuring the local disk configuration policy in the service profile using one of
the defined RAID modes for that server, or you can use the Any Configuration mode with the LSI Utilities
toolset to create the RAID volumes.
If you do not configure your RAID LUNs before installing the OS, disk discovery failures might occur during
the installation and you might see error messages such as “No Device Found.”
Server May Not Boot After RAID1 Cluster Migration if Any Configuration Mode Specified in Service Profile
After RAID1 clusters are migrated, you need to associate a service profile with the server. If the local disk
configuration policy in the service profile is configured with Any Configuration mode rather than RAID1,
the RAID LUN remains in "inactive" state during and after association. As a result, the server cannot boot.
To avoid this issue, ensure that the service profile you associate with the server contains the identical local
disk configuration policy as the original service profile before the migration and does not include the Any
Configuration 
mode.
Do Not Use JBOD Mode on Servers with MegaRAID Storage Controllers
Do not configure or use JBOD mode or JBOD operations on any blade server or integrated rack-mount server
with a MegaRAID storage controllers. JBOD mode and operations are not intended for nor are they fully
functional on these servers.
Maximum of One RAID Volume and One RAID Controller in Integrated Rack-Mount Servers
A rack-mount server that has been integrated with Cisco UCS Manager and is registered with Cisco UCS
Central can have a maximum of one RAID volume irrespective of how many hard drives are present on the
server.
All the local hard drives in an integrated rack-mount server must be connected to only one RAID Controller.
Integration with Cisco UCS Manager does not support the connection of local hard drives to multiple RAID
Controllers in a single rack-mount server. We therefore recommend that you request a single RAID Controller
configuration when you order rack-mount servers to be integrated with Cisco UCS Manager.
In addition, do not use third party tools to create multiple RAID LUNs on rack-mount servers. Cisco UCS
Manager does not support that configuration.
Cisco UCS Central Software User Manual, Release 1.2    
255
Server Policies
Guidelines for Local Disk Configuration Policies Configured for RAID