Zebra Technologies MIX05120 Prospecto

Descargar
Página de 2
FM60-2105 Operator’s Manual 
Registration Information
888-249-4855 • www.ZebraSkimmers.com • Zebra Skimmers Corporation 
Page 1
Zebra Skimmers Corp. 
MIX05120
Copyright 2008
Zebra Skimmers Corp.
PO Box 833
Chagrin Falls, OH 44022
888-249-4855
www.ZebraSkimmers.com
Printed in the USA • Revised February 2008
Zebra Economy Mixer Manual
Package Contains:
1. Drum proportioner
2. Suction tube (4 ft.) with foot valve
3. Discharge tube (4 ft.) max length 
for delivery
WEAR 
protective clothing and eyewear when dispensing chemicals or other materials.
ALWAYS 
observe safety and handling instructions of the chemical manufacturers.
ALWAYS 
direct discharge away from you or other persons or into approved containers.
ALWAYS 
dispense cleaners and chemicals in accordance with manufacturer’s instructions. Exercise CAUTION when maintaining your equipment.
CLEAN 
equipment after each use in accordance with instruction sheet.
WEAR 
protective clothing and eyewear when working in the vicinity of all chemicals, filling or emptying equipment or changing metering tips.
ALWAYS 
re-assemble equipment according to instruction procedures. Be sure all components are firmly screwed or latched into position.
ATTACH 
only to tap water outlets (75 PSI maximum).
Installation and Operation:
1. Select a metering tip (see next section), and insert it into the suction stub. Slide the open end of the suction tube through the 
bung adaptor, then over the suction stub.
2. Slide end of discharge tube over the eductor discharge outlet.
3. Remove either the 3/4 or 2-inch bung from an upright drum.
4. Insert the foot valve end of the suction tube into the drum.
5. Swivel the drum adapter several turns in the bung opening until the bracket is secure.
6. Install minimum 1/2-inch ID water hose between the inlet swivel and water supply spigot. (Minimum 25 PSI flowing water 
pressure is required to operate the unit.)
7. Turn on water supply. To begin dispensing solution, open ball valve at inlet to unit. Do not keep discharge hose in liquid! The 
concentrate will siphon from the container.
Metering Tip Selection:
The final concentration of the dispensed liquid is related to both the size of the metering tip opening (orifice) and the 
viscosity of the liquid being siphoned. If product viscosity is noticeably greater than that of water, consult the procedure for 
Measurement of Concentration on the next page to achieve your desired water-to-product ratio. For waterthin products, use 
the chart below as a guideline. Because such factors as inlet water pressure and temperature can affect dilution ratios, the 
figures listed below are only approximate. Test the actual dilution you are achieving using the Measurement of Concentration 
procedure for best results. Two undrilled, clear tips are supplied for drilling sizes not listed.
THANK YOU FOR YOUR SUPPORT OF OUR PRODUCTS
Please use this equipment carefully and observe all warnings and cautions.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -  NOTE - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 
 
 
 
Decimal 
Approximate Dilution Ratio at
 
Tip Color  
Drill Size   Equivellent 
40 PSI, water-thin viscosity (1.0 cp)
 
No tip  
 
 
4.5:1  or  22.2%
 
Gray  
30 
.1285 
5:1 
 
20.0
 
Black  
40 
.0980 
6:1 
 
16.6
 
Beige  
50  
.0700 
9:1 
 
11.1
 
Red  
55  
.0520 
20:1 
 
5.0
 
White  
57  
.0430 
24:1 
 
4.16
 
Blue  
60  
.0400 
26:1 
 
3.84
 
Tan  
65  
.0350 
31:1 
 
3.23
 
Green  
70  
.0280 
50:1 
 
2.0
 
Orange  
72  
.0250 
70:1 
 
1.43
 
Brown  
74  
.0225 
90:1 
 
1.11
 
Yellow  
76  
.0200 
100:1 
 
1.0
 
Purple  
80  
.0135 
200:1 
 
.50
 
Pink  
87  
.0100 
400:1 
 
.25
4. Metering tip kit (14 tips)
5. Product information sheet
®