BALLAST
FIG. 4 BALLAST
Location
The front door lamp ballast is located behind
the front access panel on the left side of the compo-
nent bracket.
Test Procedure
1. Disconnect the dispenser from the power source.
2. Disconnect the two terminal plug of the door
interconnect harness from the main wiring har-
ness.
3. Check the voltage across the white wire and the
blue wire terminal of the ballast with a voltmeter.
Connect the dispenser to power source. The indi-
cation must be:
a) 120 volts ac for two wire 120 volt models.
b) 120 volts ac for  three wire 120/208 volt models
or 120/240 volts models.
c) 240 volts ac for two wire 240 volt models.
If voltage is present as described the ballast is oper-
ating properly.
If voltage is not present as described, replace the
ballast.
Removal and Replacement
1.
Disconnect the wires from the ballast.
2.
Remove the one #8-32 screw securing the bal-
last to the component bracket.
3.
Remove and discard ballast.
4.
Install new ballast over the weld pin on the com-
ponent bracket  and secure with one #8-32 screw.
5.
Refer to Fig. 5  when reconnecting the wires.