ELECTRICAL REQUIREMENTS
CAUTION:  The dispenser must remain disconnected from power source until specified in Electrical Hook-Up.
 
The LCR-2 dispenser is supplied with a 120-volt / 15 Amp cord set and require a 2-wire, grounded, individual branch 
circuit rated for 120 volts AC, 15 amp, single phase, 60Hz.  The mating connector must be a NEMA 5-15R.
 
The LCR-2C dispenser is supplied with a 120-volt / 20 Amp cord set and require a 2-wire, grounded, individual branch 
circuit rated for 120 volts AC, 20 amp, single phase, 60Hz.  The mating connector must be a NEMA 5-20R.
 
These dispensers can be Field Wired for 208 or 240 volt applications. This requires a 2 or 3-wire, grounded, individual 
branch circuit rated for 208/240 volts AC, 30 amp, single phase, 60 Hz. 
NOTE:   The internal terminal block must be rewired for 208/240 applications, (see Optional Field Wiring Diagram).
120V A.C.
120V A.C.
208 or
240V A.C.
HEATER RED
208 or
240V A.C.
120V A.C.
10A. FUSE - WHITE
HEATER RED
10A. FUSE - WHITE
10A. FUSE - BLACK
LIMIT SW. - BLACK