Bunn RL00006929 Manual De Usuario

Descargar
Página de 32
Page 15
FIG. 4 WARMERS
FIG. 5 WARMERS
FIG. 6 WARMER WIRING
SERVICE (cont.)
Warmer(s)
OL: 
Brew Station & Upper
RL: 
Left Rear, Left Front, Brew Station, Right Rear & Right 
Front
Location:
  OL: One of the warmers is beneath the brew funnel 
and the other is on the top lid, FIG. 4.
  RL: These warmers include the one beneath the 
brew funnel, the ones on the right and left of the brew 
station, and the one above and to the left and right of 
the brew station as viewed from the front, FIG. 5.
Test Procedure:
1.  Once the switch has been tested and switch failure 
has been eliminated, proceed as follows.
2.  Disconnect the brewer from the power source and 
remove the #4-40 screws attaching the warmer 
being tested.
3.  Lift the warmer assembly from the brewer and 
invert the warmer making the wire terminals ac-
cessible for testing.
4.  Check for continuity from the switch to the black 
wire at the warmer element.
 
If continuity is present as described, proceed to #5.
5.  Check for continuity from the wire terminal of the 
white or red wire to the splice or indicator lamp 
using the chart below.
If continuity is present as described, proceed to #6.
If continuity is not present as described, refer to the 
Wiring Diagrams and check the brewer wiring har-
ness.
6.  Check for continuity across the two terminals on 
the warmer.
If continuity is present as described, the warmer is 
operating properly.
If continuity is not present as described, replace the 
warmer.
Removal and Replacement:
1.  Remove the #4-40 slotted-head screws holding 
the warmer to the brewer
2.  Lift the warmer assembly from the brewer.
3.  Disconnect both wires from the warmer.
4.  Refer to FIG. 6 when reconnecting the wires.
5.  Place the new warmer into the brewer and se-
curely attach it using the #4-40 screws.
MODEL
OL Upper 
WHI OR RED 
to Indicator Lamp
 
OL Brew Station 
WHI OR RED 
to Indicator Lamp
 
 
 
to Terminal Block
RL Left Rear 
WHI OR RED 
to Terminal Block
 
 
 
to Brew Station Warmer
RL Left Front 
WHI OR RED 
to Indicator Lamp
 
 
 
to Terminal Block
RL Brew Station 
WHI OR RED 
to Relay P2
 
 
 
to Left Rear Warmer
RL Right Front 
WHI OR RED 
to Right Rear Warmer
 
 
 
to Indicator Lamp
RL Right Rear 
WHI OR RED 
to Right Front Warmer
WHI or RED (see below)
BLK to Warmer Switch
P1712
P1713
P1692
32430 121699