Bunn RL00006929 Manual De Usuario

Descargar
Página de 32
Page 20
FIG. 18 LIMIT THERMOSTAT
FIG. 19 LIMIT THERMOSTAT WIRING
SERVICE (cont.)
Limit Thermostat
4.  Check for continuity across the limit thermostat 
terminals. 
If continuity is present as described, the limit thermo-
stat is operating properly.
If continuity is not present as described, replace the 
limit thermostat.
Removal and Replacement:
1.  Remove both wires from the limit thermostat 
terminals.
2.  Carefully slide the limit thermostat out from under 
the retaining clip.
3.  Carefully slide the new limit thermostat into the 
retaining clip.
4.  Refer to FIG. 19 when reconnecting the wires.
Location:
The limit thermostat is located on the back of the tank 
assembly, FIG. 18.
Test Procedure:
1.  Disconnect the brewer from the power source.
2.  Check voltage across the black wire from the limit 
thermostat and the white or red wire on the tank 
heater terminal. Connect the brewer to the power 
source. The indication must be:
 
a) 120 volts ac for two wire 120 volt models.
 
b) 200 or 240 volts ac for two wire 200 volt or 
240 volt models and three wire 120/240 volt 
models.
 
c) 100 volts ac for two wire 100 volt models.
3.  Disconnect the brewer from the power source.
If voltage is present as described, proceed to #4.
If voltage is not present as described, refer to the Wir-
ing Diagrams and check the brewer wiring harness.
P1715
P1984
BLK to Terminal Block
BLU to BLU Lead from 
Control Thermostat
32430 070700