Bunn TW Manual De Usuario

Descargar
Página de 32
Page 8
TROUBLESHOOTING
A  troubleshooting  guide  is  provided  to  suggest  probable  causes  and  remedies  for  the  most  likely  problems
encountered.    If  the  problem  remains  after  exhausting  the  troubleshooting  steps,  contact  the  Bunn-O-Matic
Technical Service Department.
Inspection, testing, and repair of electrical equipment should be performed only by qualified service person-
nel.
All electronic components have 120 volt ac and low voltage dc potential on their terminals.  Shorting of
terminals or the application of external voltages may result in board failure.
Intermittent operation of electronic circuit boards is unlikely.  Board failure will normally be permanent.  If an
intermittent condition is encountered, the cause will likely be a switch contact or a loose connection at a
terminal or crimp.
Solenoid removal requires interrupting the water supply to the valve.  Damage may result if solenoids are
energized for more than ten minutes without a supply of water.
The use of two wrenches is recommended whenever plumbing fittings are tightened or loosened.  This will
help to avoid twists and kinks in the tubing.
Make certain that all plumbing connections are sealed and electrical connections tight and isolated.
This brewer is heated at all times.  Keep away from combustibles.
WARNING –
• Exercise extreme caution when servicing electrical equipment.
• Unplug the brewer when servicing, except when electrical tests are specified.
• Follow recommended service procedures
• Replace all protective shields or safety notices
Problem
Brew cycle(s) will not start
Probable Cause
1. No water
2. No power or incorrect voltage to
the brewer
3.  External  Strainer/  Flow  Control
(.750 GPM)
4. TEA/OFF/COFFEE Switch
5. Start Switch
Remedy
Water lines and valves to the brewer
must be open.
Check circuit breakers or fuses.
(A) Direction of flow arrow must be
pointing towards the brewer.
(B) Remove the strainer/flow con-
trol  and  check  for  obstructions.
Clear or replace.
Refer to 
Service - TEA/OFF/COFFEE
Switch for testing. See page 26
Refer to 
Service - Start Switch for
testing procedures. See page 27
10510  071000