SERVICE (cont.)
8.
Disconnect the black wire and the white or red
wire from the tank heater terminals.
9.
Remove  the  three  #8-32  nuts  and  holddown
brackets securing the tank lid to the tank.
10. Remove the tank lid with level probe.
11. Remove  the  switch  panel  and  disconnect  the
leads to the tank "Keep Warm" heater.
12. On  100  volt  models  equipped  with  rear  drain,
open the shut-off valve and drain water from the
tank.  Disconnect  drain  tube  and  fittings  from
tank.
13. Direct the pink probe wire, capillary tube and top
warmer wiring harness through the nylon bush-
ing located on the rear of the basin flange.
14. Lift  tank  and  fill  basin  assembly  from  housing
and drain water from tank.
15. Remove  the  two  hex  nuts  securing  the  tank
heater to the bottom of tank. Remove tank heater
with gaskets and discard.
16. Install new tank heater with gaskets to the tank
and secure with two hex nuts.
17. Install tank with limit thermostat, sprayhead tube
and tank heater.
18. Reconnect the inlet and outlet water lines to the
solenoid and faucet.
19. Secure spayhead tube to hood using a  hex nut.
20. Install sprayhead.
P1593
FIG. 13 TANK HEATER TERMINALS
WHI or RED Wire
From Tank Heater
BLK Wire to Limit
Thermostat
29251 052500
TANK HEATER (Cont.)
21. Reconnect the wires to the limit thermostat and
control  thermostat.  See  limit  thermostat  and
control thermostat sections in this manual when
reconnecting wires.
22. Install tank lid with holddown brackets and #8-32
nuts
23. Install the thermostat capillary bulb as described
in section for control thermostat.
24. Reconnect the wire to the liquid level probe.
25. Refer  to  FIG.  13  when  reconnecting  the  tank
heater wires.