REGULATING THE MINIMUM OUTPUT OF THE HOB BURNERS 
Normal/valve taps: 
Ignite the burners and turn the knob to the maximum position. Remove the knob and insert a 
small flat-head screwdriver into the rod or through the holes on the side of the control panel, in 
accordance with the type (fig. 8 A/B). Loosen the by-pass screw by two turns in an anti-clockwise 
direction and rotate the rod to the minimum position. Adjust the previously loosened screws until 
the flame is lowered but stable, even when rapid changes are made from the maximum to the 
minimum position with the burner cold. If safety taps are fitted, let the burner run on minimum for 
a few minutes to ensure that the device does not cut in. If it does, increase the minimum. 
N.B.   For  liquid  gas  settings,  the  burner  minimum  must  be  set  by  fully  tightening  the  tap 
by-passes. 
 
      
   Fig.8     
 
 
 
 
                                                    
 WARNINGS: 
If the  burner  flames  accidentally  go  out, turn  off the  KNOB  and  wait  for  at  least one  minute 
before igniting. 
Using a gas cooker produces heat and humidity in the room where it is installed. Ensure the 
room is well ventilated by keeping all the natural air vents open or by installing an extraction 
hood with flue pipe. 
Intensive or extensive use of the cooker may require  supplementary ventilation e.g. opening 
a  window,  or  more  efficient  ventilation  e.g.  increasing  the  capacity  of  the  mechanic 
ventilation, if installed. 
 
 
N.B. When the burners are alight, there must not be any draughts inside the room in 
that they may affect the flame or even blow it out.