Blue Coat Systems SG Appliance Manual De Usuario

Descargar
Página de 108
Volume 9: Managing the Blue Coat SG Appliance
22
SGOS#(config snmp) trap-community password
To set them as encrypted:
SGOS#(config) snmp
SGOS#(config snmp) enable
SGOS#(config snmp) encrypted-read-community encrypted-password
SGOS#(config snmp) encrypted-write-community encrypted-password
SGOS#(config snmp) encrypted-trap-community encrypted-password
Configuring SNMP Traps
The SG appliance can send SNMP traps to a management station as they occur. By default, 
all system-level traps are sent to the address specified. You can also enable authorization 
traps to send notification of attempts to access the Management Console. Also, if the 
system crashes for whatever reason, a cold start SNMP trap is issued on power up. No 
configuration is required.
To enable SNMP traps:
1.
Select 
Maintenance > SNMP > Traps
.
2.
In the 
Send traps to
 fields, enter the IP address(es) of the workstation(s) where traps 
are to be sent.
3.
To receive authorization traps, select 
Enable authorization traps
.
4.
Select 
Apply
 to commit the changes to the SG appliance.
Related CLI Commands for Enabling SNMP Traps
SGOS#(config snmp) trap-address {1 | 2 | 3} ip_address
Indicates which IP address(es) can receive traps and in which priority.
SGOS#(config snmp) authorize-traps
Note:
The SNMP trap for CPU utilization is sent only if the CPU continues to stay up for 
32 or more seconds.
Note:
You cannot configure SNMP traps to go out through a particular interface. The 
interface that is configured first is used until it fails and is used to identify the device.