2.2.8. Electrical 
Requirements 
 
The CMA-180 comes standard factory, wired for 3-phase operation.  Check the electrical data 
plate to confirm this.  If the account requires 1 phase, refer to “Electrical Requirements”, Section 
1-A, for proper wiring instruction for conversion.  Also check the wiring diagram to properly wire 
the terminal power block, tank heater, and booster heater for 1 phase (or 1B diagram below). 
 
SINGLE PHASE POWER 
 
NOTE:  80 amp service is required when CMA-180 is wired for single-phase with the booster 
heater.  See “Electrical Requirements” section for DUAL 1-phase power supply.  Circuit breaker 
requirement (1) 50 amp & 30 amp.   
Figure 1-B 
 
             Single Phase         
 
                              Single Phase           
         
 
 
 
 
          
 
             Rinse Booster Heater 
 
 
      Wash Tank Heater
 
 
 
1.  Install booster heater 
 
 
1.  Install wash heater bus   
 
     wires and bus bars as   
 
     bars as shown above. 
 
 
2.  Connect wire #59 to 
 
 
2.  Connect wire #15 to 
 
     heater L1.  
 
 
 
     heater L1. 
 
 
3.  Connect wire #57 to 
 
 
3.  Connect wire #17 to 
 
     heater L2.  
 
 
 
     heater L2.  
 
 
 
 
 
 
 