Genie 3024 Manual De Usuario

Descargar
Página de 26
©2010     The Genie Company 
01/27/2010
19
Independent Light Control Button
– Controls door opener lights from inside garage
– Shuts OFF lights 4 minutes after door action
Vacation Lock Button
– LOCK disables controls  
 
  after door is completely    
 closed
– UNLOCK allows controls to  
  work normally
Indicator Light
Red indicator light is always ON
When Vacation Lock is ON the 
indicator light flashes
Open/Close Button
Open and closes door from inside garage
WALL CONSOLE - OVERVIEW
Use only the Series III wall console provided with this 
unit.  Wall consoles from other manufacturers will not 
work with this power head.  
Earlier Genie® 
Series II 
wall consoles will not work with this power head
.
Wall console has three buttons and one indicator light. 
Indicator Light
Indicator light will display red when wall console 
is properly wired and Vacation Lock is OFF.  When 
Vacation Lock is ON indicator light flashes.
Open/Close Button
Use this button to open or close garage door.  When 
Vacation Lock is ON the Open/Close button will 
CLOSE door only.  Note: Constant button pressure in 
the CLOSE mode will override error responses in the 
power head and close door. 
Independent Light Control Button
Use this button to turn power head lights ON.  Power 
head lighting will remain ON until this button is 
pressed again or a door action has been completed.  
Note: If opener has a Motion Detector sensor the 
sensor will keep power head lights ON as long as 
motion is detected.
Vacation Lock Button
When Vacation Lock is ON the power head cannot be 
activated by the wall console or a remote.
•  Press and hold for 5 seconds (or till Indicator Light 
flashes) to activate Vacation Lock.
•  Press and release to turn Vacation Lock OFF
OPTIONAL DUAL WALL CONSOLE - INSTALLATION
Use only the 
Series III 
wall console provided with this 
unit.  An optional second 
Genie® Series III 
wall console 
(not provided) can be added.  
OR
STB
BWC
IWC
NOT
USED
NOT
USED
FROM STBs
FROM WALL
CONSOLE #1
FROM WALL
CONSOLE #2
TO 
POWER HEAD
WALL
CONSOLE #1
WALL
CONSOLE #2
TO WALL CONSOLE #1
W
B/W
W
B/W
W
B/W
W
B/W
BOTH TO POWER HEAD
WALL
CONSOLE #1
WALL
CONSOLE #2
STB
BWC
IWC
NOT
USED
NOT
USED
NOT
USED
NOT
USED
FROM STBs
FROM WALL
CONSOLE
Tip: If indicator light on wall console comes ON, but 
there is NO 
operation from 
buttons - 
verify 
wall console 
wire 
routing 
at power head 
connector. 
STB
BWC
IWC
NOT
USED
NOT
USED
NOT
USED
NOT
USED
FROM STBs
FROM WALL
CONSOLE
STB
BWC
IWC
FRO  STBs
FROM WALL
CONSOLE
STB
BWC
IWC
OM STBs
ROM WA
OM W
OLE
ONSO
CHANGE LIGHT BULBS
 
WARNING
 
•   Observe all safety warning and precautions! 
Improper light bulb removal or replacement 
could result in Death or Serious Injury.
•   Disconnect power from opener before 
beginning this task.
•   When replacing light cover, make sure wires are 
not pinched or near moving parts.
1.  Disconnect power to door opener.
•  Open power head light cover.
•  Remove light bulb(s).
•  Replace with maximum 100 Watt light bulbs.
– Do NOT use light bulbs with greater than 100 
Watt rating.
•  Close power head light cover.
2.  Reconnect power to door opener.
•  Test light operation.