Maytag MER6875AAB/F/N/Q/S/W Manual De Usuario

Descargar
Página de 85
Testing Procedures 
 
!
WARNING
 
To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless  
testing requires power. 
16 
16023416 
©2004 Maytag Services 
 
 
Illustration Component 
Test 
Procedure 
Results 
 
 
Oven indicator light 
and 
Surface indicator light 
Measure voltage at indicator light. .......  If 
voltage is present and light does not 
work replace light. 
If no voltage is present at indicator light 
check wiring. 
 
 
Rocker switch 
Measure continuity of switch positions: 
Closed...............................................
Open .................................................
 
Continuity 
Infinite 
 
 
Door plunger switch 
Measure continuity at the following 
points: 
C-NO ...............................................  
 
 
Plunger in continuity, Plunger out infinite. 
 
 
Autolatch assembly 
with switch 
Disconnect wires and test for 
continuity per wiring diagram. 
See wiring diagram for schematic layout. 
Refer to Parts Manual for correct 
autolatch switch associated with the 
correct manufacturing number. 
 
Convection Assembly 
Convection Element 
Convection Motor 
Measure voltage..................................  
Remove wires, check resistance .........  
Check motor windings to ground .........  
Motor speed ........................................  
120 VAC. 
Approximately 30 
Ω. 
No continuity. 
Approx. 900 RPM. 
 
 
Limiter Normally 
Closed 
Verify proper operation. 
Open ............. Approx. 216°F............  
Closed........... Approx. 176°F............  
 
 
Infinite 
Continuity 
 
 
Temperature sensor 
Measure resistances ...........................  
Approximately 1100 
Ω at room 
temperature 75
°F.