Repair 
18
332245E
Disconnect the Air Motor
1.
Flush the pump, if possible. Se
Flush, page 10
Relieve the pressure. Se
2.
Disconnect the air hose, fluid hoses, and the ground 
wire (109).
3.
Hold the flats of the air motor piston rod with a 
wrench. Use another wrench to loosen the coupling 
nut (106).
4.
Use a 23 mm socket to remove the tie rod nuts 
(105).
5.
Use a 13 mm socket to remove the top two mount-
ing screws (209).
6.
Lift up on the air motor to remove it. The tie rods 
(104) and will remain attached.
NOTE: Remove the two screws on the arms and tip 
back or remove the air control panel for easier removal 
of the air motor.
7.
Use a socket on the flats of the tie rods (104) to 
remove them from the bottom cover of the air motor.
NOTE: See air motor manual for service and parts infor-
mation.
Reconnect the Air Motor
1.
Screw the tie rods (104) into the bottom cover of the 
air motor. Torque to 50-55 ft-lb (68-75 N•m).
2.
Align the tie rods (104) with the holes in the pump 
adapter (103). Carefully lower the air motor into 
place.
3.
Attach the tie rod nuts (105) and torque to 50-60 
ft-lb (68-81 N•m).
4.
Tighten the mounting screws (209).
5.
Hand tighten the coupling nut (106), then torque to 
75-80 ft-lb (102-108 N•m).
6.
Connect the air hose, fluid hose, and the ground 
wire.
ti12819a
104
105
103
209