Graco 332245E Manual De Usuario

Descargar
Página de 30
Performance Charts 
26
332245E
Performance Charts
Calculate Fluid Outlet Pressure
To calculate fluid outlet pressure (psi/MPa/bar) at a spe-
cific fluid flow (gpm/lpm) and operating air pressure 
(psi/MPa/bar), use the following instructions and pump 
data charts.
1.
Locate desired flow along bottom of chart.
2.
Follow vertical line up to intersection with selected 
fluid outlet pressure curve. Follow left to scale to 
read fluid outlet pressure.
Calculate Pump Air Flow/Consumption
To calculate pump air flow/consumption (scfm or 
m
3
/min) at a specific fluid flow (gpm/lpm) and air pres-
sure (psi/MPa/bar), use the following instructions and 
pump data charts.
1.
Locate desired flow along bottom of chart.
2.
Follow vertical line up to intersection with selected 
air flow/consumption curve. Follow right to scale to 
read air flow/consumption
Merkur X48
48:1 Ratio, 75 cc/cycle
Cycles per Minute
0
0
Fluid Flow gpm (lpm) tested in No. 10 weight oil
Fluid Out
le
t P
re
ss
ur
e ps
i (MPa
, ba
r)
Air Flow s
cf
m (m
3
/min)
0.2
(0.75)
0.4
0.6
0.8
1.0
(1.5)
(2.3)
(3.0)
(3.8)
1.2
(4.5)
10
20
30
40
50
60
1000
(7, 70)
3000
4000
5000
6000
(14, 140)
(21, 210)
(28, 280)
(35, 350)
(42, 420)
2000
10
20
30
40
50
60
(0.3)
(0.6)
(0.9)
(1.1)
(1.4)
(1.7)
A
B
C
A
B
C
Key: 
A
100 psi (0.69 MPa, 6.9 bar)
B
70 psi (0.48 MPa, 4.8 bar)
C
40 psi (0.28 MPa, 2.8 bar)
 Fluid Flow
 Air Flow