Operation
Operation
Pressure Relief Procedure
This equipment stays pressurized until pressure
is manually relieved. To help prevent serious
injury from pressurized fluid, such as skin injection,
splashing fluid and moving parts, follow the
Pressure Relief Procedure when you stop spraying
and before cleaning, checking, or servicing the
equipment.
1. Turn OFF (O) the ES On/Off switch.
2. Engage the trigger lock.
3. Turn off the air bleed valves to the fluid source
and to the gun.
4. Disengage the trigger lock.
5. Trigger the gun into a grounded metal waste
container to relieve the fluid pressure.
6. Engage the trigger lock.
7. Open the pump drain valve, having a waste
container ready to catch the drainage. Leave
the pump drain valve open until you are ready
to spray again.
8. If the spray tip or hose is completely clogged or
pressure is not fully relieved, slowly loosen the
hose end coupling. Now clear the spray tip or
hose.
Startup
Follow all steps under
Shutdown
1. Flush the gun. See
2. Follow the
3. Hang the gun from its hook, with the nozzle
pointing down.