Graco 257060 Manual De Usuario

Descargar
Página de 34
Operation
313034A
9
Operation
Trigger Lock
Always engage the trigger lock when you stop 
spraying to prevent the gun from being triggered 
accidentally by hand or if dropped or bumped.
Pressure Relief Procedure
Follow this Pressure Relief Procedure whenever 
you stop spraying and before cleaning, checking, 
servicing, or transporting equipment. 
1. Turn power switch OFF and unplug 
power cord.
2. Turn Prime/Spray valve to 
PRIME to relieve pressure. 
3. Hold gun firmly to side of 
pail. Trigger the gun to 
relieve pressure.
4. Engage trigger lock. 
If you suspect the spray tip or hose is clogged or 
that pressure has not been fully relieved after fol-
lowing the steps above, VERY SLOWLY loosen tip 
guard retaining nut or hose end coupling to relieve 
pressure gradually, then loosen completely. Clear 
hose or tip obstruction. Read Unclogging Spray 
Tip, page 13.
ti8908a
Trigger Locked
Trigger Unlocked
ti8909a
ti2810a
Leave Prime/Spray valve in the PRIME 
position until you are ready to spray again.
ti9346a
ti11986a
ti8908a
Pressure Control Knob Settings
High Pressure
 
Spray
Low Pressure
 
Spray
Prime/
 
Clean
Rolling
ti5597a
To select function, align symbol on pressure control knob with setting indicator on sprayer.