Graco Inc. ti12008a Manual De Usuario

Descargar
Página de 30
Power Cord Replacement 
26
310824D
Power Cord Replacement
See Wiring Diagram, page 28.
Removal
1.
Follow Control Board Replacement removal 
instructions, steps 1-8, page 20.
2.
Disconnect green ground wire (G) from sprayer by 
loosening grounding screw (31).
Installation 
1.
Follow Control Board Replacement installation 
instructions, steps 1-4, page 20. 
2.
Reconnect, green ground wire (G) to green ground-
ing screw (31) on frame. Be sure terminal on ground 
faces UP or wires could get caught in shroud.
3.
Reattach motor connector (B) and pressure control 
switch connect (A). 
4.
Install shroud (29) and two screws (30).
WARNING
Read Electric Shock Warning, page 3 and Pressure 
Relief Procedure
, page 8.
33
33
240V
120V
G
31