Bosch 20 Manual De Usuario

Descargar
Página de 10
 
B
osch Security Systems
 
 | April 03 | 3922 988 97112 en
 
en
 
 | 8
 
Digital Congress Network
 
 | TCB 4 Upgrade Kit LBB 3519/20 | Chapter 3. CCU Protocol and Serial Port settings
 
Chapter 3. CCU Protocol and Serial Port settings
 
For location of DIP-switches see 
fig. 2-1
 
3.1  LBB 3500/xx (TCB 4) - Port 1 : DCN Control PC                                        
Port 2 : Camera Control 
 
In a single (stand-alone) CCU systems two serial COM-ports (Port 1 and Port 2) are    
available. Both ports can be individually configured. Default settings are;
8 data bits
No parity check
1 Stop bit
 
NOTE: 
 
It is possible to select ‘Full’ protocol on both Port 1 and Port 2.  However this is NOT 
recommended due to processing power and memory limitations.
 
Table 3.1 :  LBB 3500/xx Protocol settings 
 
DIP-switch S14
                Port 1
              Port 2
Switch
Switch
Switch
Switch
DP-1
DP-2
DP-5
DP-6
 
Simple (Open interface)
OFF
OFF
OFF
OFF
Terminal
OFF
ON
OFF
ON
Full 
ON*
OFF*
ON
OFF
Camera control
ON
ON
ON*
ON*
* default settings 
 
Table 3.2 :   LBB 3500/xx Baud rate settings
 
DIP-switch S14
               Port 1
               Port 2
Switch
Switch
Switch
Switch
DP-3
DP-4
DP-7
DP-8
 
9.6 K
OFF
OFF
OFF
OFF
19.2 K
OFF
ON
OFF*
ON*
57.6 K
ON
OFF
ON
OFF
115.2 K
ON*
ON*
ON
ON
* default settings
 
DIP-switch S14 (default settings)
ON
S14
8 7 6 5 4 3 2 1
Port 1 default
ON
S14
8 7 6 5 4 3 2 1
Port 2 default