Bosch 20 Manual De Usuario
B
osch Security Systems
| April 03 | 3922 988 97112 en
en
| 8
Digital Congress Network
| TCB 4 Upgrade Kit LBB 3519/20 | Chapter 3. CCU Protocol and Serial Port settings
Chapter 3. CCU Protocol and Serial Port settings
For location of DIP-switches see
fig. 2-1
3.1 LBB 3500/xx (TCB 4) - Port 1 : DCN Control PC
Port 2 : Camera Control
In a single (stand-alone) CCU systems two serial COM-ports (Port 1 and Port 2) are
available. Both ports can be individually configured. Default settings are;
•
available. Both ports can be individually configured. Default settings are;
•
8 data bits
•
No parity check
•
1 Stop bit
NOTE:
It is possible to select ‘Full’ protocol on both Port 1 and Port 2. However this is NOT
recommended due to processing power and memory limitations.
Table 3.1 : LBB 3500/xx Protocol settings
DIP-switch S14
Port 1
Port 2
Switch
Switch
Switch
Switch
DP-1
DP-2
DP-5
DP-6
Simple (Open interface)
OFF
OFF
OFF
OFF
Terminal
OFF
ON
OFF
ON
Full
ON*
OFF*
ON
OFF
Camera control
ON
ON
ON*
ON*
* default settings
Table 3.2 : LBB 3500/xx Baud rate settings
DIP-switch S14
Port 1
Port 2
Switch
Switch
Switch
Switch
DP-3
DP-4
DP-7
DP-8
9.6 K
OFF
OFF
OFF
OFF
19.2 K
OFF
ON
OFF*
ON*
57.6 K
ON
OFF
ON
OFF
115.2 K
ON*
ON*
ON
ON
* default settings
DIP-switch S14 (default settings)
ON
S14
8 7 6 5 4 3 2 1
Port 1 default
ON
S14
8 7 6 5 4 3 2 1
Port 2 default