IBM 4365 Manual De Usuario

Descargar
Página de 76
Serial
 
port
 
problems
 
 
v
   
Follow
 
the
 
suggested
 
actions
 
in
 
the
 
order
 
in
 
which
 
they
 
are
 
listed
 
in
 
the
 
Action
 
column
 
until
 
the
 
problem
 
is
 
solved.
 
v
   
See
 
the
 
parts
 
listing
 
in
 
the
 
Problem
 
Determination
 
and
 
Service
 
Guide
 
to
 
determine
 
which
 
components
 
are
 
customer
 
replaceable
 
units
 
(CRU)
 
and
 
which
 
components
 
are
 
field
 
replaceable
 
units
 
(FRU).
 
v
   
If
 
an
 
action
 
step
 
is
 
preceded
 
by
 
“(Trained
 
service
 
technician
 
only),”
 
that
 
step
 
must
 
be
 
performed
 
only
 
by
 
a
 
trained
 
service
 
technician.
 
Symptom
 
Action
 
The
 
number
 
of
 
serial
 
ports
 
that
 
are
 
identified
 
by
 
the
 
operating
 
system
 
is
 
less
 
than
 
the
 
number
 
of
 
installed
 
serial
 
ports.
 
1.
   
Make
 
sure
 
that:
 
v
   
Each
 
port
 
is
 
assigned
 
a
 
unique
 
address
 
in
 
the
 
Configuration/Setup
 
Utility
 
program
 
and
 
none
 
of
 
the
 
serial
 
ports
 
are
 
disabled.
 
v
   
The
 
serial-port
 
adapter
 
(if
 
one
 
is
 
installed)
 
is
 
seated
 
correctly.
2.
   
Reseat
 
the
 
serial
 
port
 
adapter.
 
3.
   
Replace
 
the
 
serial
 
port
 
adapter.
 
A
 
serial
 
device
 
does
 
not
 
work.
 
1.
   
Make
 
sure
 
that:
 
v
   
The
 
device
 
is
 
compatible
 
with
 
the
 
server.
 
v
   
The
 
serial
 
port
 
is
 
enabled
 
and
 
is
 
assigned
 
a
 
unique
 
address.
 
v
   
The
 
device
 
is
 
connected
 
to
 
the
 
correct
 
connector
 
(see
 
2.
   
Reseat
 
the
 
following
 
components:
 
a.
   
Failing
 
serial
 
device
 
b.
   
Serial
 
cable
3.
   
Replace
 
the
 
following
 
components
 
one
 
at
 
a
 
time,
 
in
 
the
 
order
 
shown,
 
restarting
 
the
 
server
 
each
 
time:
 
a.
   
Failing
 
serial
 
device
 
b.
   
Serial
 
cable
 
c.
   
(Trained
 
service
 
technician
 
only)
 
System
 
board
  
ServerGuide
 
problems
 
 
v
   
Follow
 
the
 
suggested
 
actions
 
in
 
the
 
order
 
in
 
which
 
they
 
are
 
listed
 
in
 
the
 
Action
 
column
 
until
 
the
 
problem
 
is
 
solved.
 
v
   
See
 
the
 
parts
 
listing
 
in
 
the
 
Problem
 
Determination
 
and
 
Service
 
Guide
 
to
 
determine
 
which
 
components
 
are
 
customer
 
replaceable
 
units
 
(CRU)
 
and
 
which
 
components
 
are
 
field
 
replaceable
 
units
 
(FRU).
 
v
   
If
 
an
 
action
 
step
 
is
 
preceded
 
by
 
“(Trained
 
service
 
technician
 
only),”
 
that
 
step
 
must
 
be
 
performed
 
only
 
by
 
a
 
trained
 
service
 
technician.
 
Symptom
 
Action
 
The
 
ServerGuide
 
Setup
 
and
 
Installation
 
CD
 
will
 
not
 
start.
 
1.
   
Make
 
sure
 
that
 
the
 
server
 
supports
 
the
 
ServerGuide
 
program
 
and
 
has
 
a
 
startable
 
(bootable)
 
CD
 
or
 
DVD
 
drive.
 
2.
   
If
 
the
 
startup
 
(boot)
 
sequence
 
settings
 
have
 
been
 
changed,
 
make
 
sure
 
that
 
the
 
CD
 
or
 
DVD
 
drive
 
is
 
first
 
in
 
the
 
startup
 
sequence.
 
3.
   
If
 
more
 
than
 
one
 
CD
 
or
 
DVD
 
drive
 
is
 
installed,
 
make
 
sure
 
that
 
only
 
one
 
drive
 
is
 
set
 
as
 
the
 
primary
 
drive.
 
Start
 
the
 
CD
 
from
 
the
 
primary
 
drive.
 
The
 
ServeRAID
 
program
 
cannot
 
view
 
all
 
installed
 
drives,
 
or
 
the
 
operating
 
system
 
cannot
 
be
 
installed.
 
1.
   
Make
 
sure
 
that
 
there
 
are
 
no
 
duplicate
 
or
 
IRQ
 
assignments.
 
2.
   
Make
 
sure
 
that
 
the
 
hard
 
disk
 
drive
 
is
 
connected
 
correctly.
 
3.
   
Make
 
sure
 
that
 
the
 
hard
 
disk
 
drive
 
cables
 
are
 
securely
 
connected.
 
 
46
 
IBM
 
System
 
x3250
 
Types
 
4364
 
and
 
4365:
 
Installation
 
Guide