34          Maintaining and Troubleshooting the Gateway ALR 8300 Server
SHM mode jumper
The SHM mode jumper indicates whether the system board is installed in a 
tower or rack system. When the system board is installed in a tower chassis, 
leave the jumper pins unconnected. When the system board is installed in a 
rack, the jumper pins must be connected. The SHM software checks the 
status of this jumper to determine whether the configuration and other 
characteristics of the server are correct for a system of the appropriate type.
1.
Turn off the system and disconnect the power cord.
2.
Open the case, observing the ESD precautions in “Static electricity 
precautions” on page 2.
3.
Install a jumper shunt on the jumper to connect the pins.
4.
Close the case, as described in “Closing the system” on page 7.
5.
Reconnect the power cord and turn on the system.
To Set the SHM Mode Jumper