  Delta Temperature Controller User Manual 
 
© DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED                 - 3 - 
    2007-09-17
 
CHAPTER 1: 
D
EFAULT 
S
ETTINGS OF 
P
ARAMETERS 
1.1  Default Settings in Temperature Controller 
 
DTA 
DTB 
DTC 
Model: DTA4896R1 
Model: DTB4896RR 
Model: DTC1000R 
PV 
SV 
PV 
SV 
PV 
SV 
 
 
 
 
Not connected 
to sensor 
0.0 
Press 
 for 
more than 3 
seconds to 
enter initial 
setting mode 
 
Press 
 for 
more than 3 
seconds to 
enter initial 
setting mode 
 
Set up control modes 
 
 
 
 
Control mode  PID control 
 
 
 
 Run/stop 
Run 
 
 
 
 
Output 1 
Heating 
 
 
 
 Output 
Heating 
 
 
 
 
Status of key 
Normal 
 
 
 
 Auto-tuning 
End 
 
 
 
 
Set up temperature 
 
 
 
 Input 
type 
PT100 
 
 
 
 
Input unit 
°C 
 
 
 
 Set 
value 
0.0 
 
 
 
 
Maximum input 
temperature 
600.0 
 
 
 
 Minimum 
input 
temperature 
-20.0 
 
 
 
 
Position of 
decimal point 
1 digit after 
decimal point 
 
 
 
 
Set up PID parameter 
 
 
 
 
Proportional 
band (P) 
47.6 
 
 
 
 
Integral time (I)  260 
 
 
 
 
Derivative time 
(D) 
41 
 
 
 
 
Control cycle 1  20 
 
 
 
 
Integral default 
value 
0.0 
 
 
 
 
Control cycle 2  20