ServSwitch Wizard VGA (USB)
724-746-5500   |   blackbox.com 
Page 22
724-746-5500   |   blackbox.com 
1
2
3
4
USB2.0
SWITCHED
USB 1
USB 2
5V
4A
INDOOR
USE
ONLY
USER
CONSOLE
OPTIONS
V1
V2
V3
V4
Display
1
Display
2
Display
3
Display
4
Computer
1
EDID
Computer
2
EDID
Computer
3
EDID
Computer
4
EDID
3.2.6 Managing EDID video display information
Whenever a ServSwitch Wizard VGA (USB) unit is powered on (or when the option
F 2 is selected from the configuration menu),
it will interrogate the connected monitor(s) to determine whether EDID (Extended Display Identification Data) information is avail-
able. If EDID information is available, it will be copied and used; otherwise a default set of data, stored within the ServSwitch
Wizard VGA (USB), will be substituted. You can also optionally choose to prevent the unit from seeking new EDID information
and instead rely only on stored data.
EDID Emulation
The ServSwitch Wizard VGA (USB) units use an
EDID Emulation feature to ensure that the collected EDID information (up to two
pages) is correctly supplied to every connected computer, whether it is currently selected or not. See Figure 3-16.
Figure 3-16. How EDID information is disseminated across the computers
3.2.6.1 Refreshing EDID information during use
You can refresh the EDID information from the connected monitor(s) without the need to power cycle the ServSwitch Wizard
VGA (USB).
To refresh EDID information during use
1  Enter the Configuration menu (see Section 4.1 for details).
2  Press
F to enter the Functions menu
3  Press
2 and then Enter.
4  Press
E and then Enter to exit the menu.
3.2.6.2 Using stored EDID information only
You can choose to prevent the unit from interrogating the video display(s) during startup. When you invoke this option, the unit
will only use the EDID information that it has already stored and pass this on to the connected computers. To revert to interrogat-
ing the video display, use the
F 2 function discussed above.
To use the stored EDID information at the power up
1  Enter the Configuration menu (see Section 4.1 for details).
2  Press
F to enter the Functions menu
3  Press
3 and then Enter.
4  Press
E and then Enter to exit the menu.