GarrettCom Magnum 6K32T Manual De Usuario

Descargar
Página de 67
Magnum 6K32 & 6K32T Managed Switch                 Installation and User Guide (12/05) 
 
www  GarrettCom  com
.
.
Fiber connector types supported: 
  
 ST-type 
(twist-lock) 
 
  
 SC-type 
(snap-in) 
 
   
MTRJ-type Small Form Factor (SFF) 
 
   
LC-type    Small Form Factor (SFF)  
  
 GBIC 
modules 
 
 
 
 
LEDs: Per Port 
  
LK: 
Steady ON when media link is operational  
 
 
ACT: ON with receiver port activity 
 
 
FDX/HDX:  ON = Full-Duplex Mode 
 
 
                     OFF = Half-Duplex Mode 
 
 
100/10: ON = 100Mbps speed 
 
 
 
       OFF = 10 Mbps   
 Operating 
Environment 
 
UL 60950 “Component Parts” temp. ratings:  130
° F (55°C) 
 
IEC 60068 “Type Test” ratings:- -40
°to 185°F (-40°to 85°C) 
 
 
Ambient Relative Humidity:  5% to 95% (non-condensing) 
 
 
Altitude: -200 to 13,000 ft. (-60 to 4000m) 
 
 
Conformal Coating (Humidity Protection) option: Request quote 
 Packaging 
 
 
Enclosure:  Rugged High strength metal. Suitable for stand-alone    
 
 
 
or rack-mounting  
 
 
 
  
 
 
Dimensions:   1.70in. H x 17.0in. W x 9.0in.  D 
 
 
 
4.32cm H x 43.2cm W x 22.9cm D  
 
 
Cooling method:  Fan cooled, @ 3@ 7 cfm ea. 
 
Management Console connector 
 
DB-9 for RS-232 “ null-modem “ cable (sometimes called an X-modem cable) 
 
Power Supply (Internal) 
 
AC Power Connector:  IEC-type, male recessed at rear of chassis,  
with adjacent manual ON-OFF switch (optional if no Alarms Cont.) 
 
Input Voltage:  100 to 240 VAC (auto-ranging) 
 
Input Frequency:  47 to 63 Hz (auto-ranging) 
 
Power Consumption: 45 watts max  (with fiber module) 
 
 
 
                     30 watts for a fully-loaded copper only model 
 
Fuse required for replacement- 1 Amps 
        DC Power Supply (Options) 
-48VDC Power Input Voltage : -36 to -70 VDC  
Fuse Required – 2Amps 
 24VDC Power Input Voltage : 20 to 40VDC 
Fuse Required – 3Amps 
125VDC Power and 100VDC Input Voltage : 88 to 300VDC 
Fuse Required – 1Amps 
Std. Terminal Block :   “ -, GND, + ” 
Power Consumption: same as for AC models, see above 
Warning- All the fuse replacment must be replaced with same value.