1. 
Before connecting the fiber optic cable, remove the protective dust caps from the
 
tips of the connectors on the PM-ST.  Save these dust caps for future use. 
2. 
Wipe clean the ends of the dual connectors with a soft cloth or lint-free lens tissue 
dampened in alcohol.  Make certain the connectors are clean before connecting. 
 
Note: 
One strand of the duplex fiber optic cable is coded using color bands 
 
at regular intervals; you must use the color-coded strand on the 
 
associated ports at each end of the fiber optic segment. 
 
3.  Connect the Transmit (TX) port (light colored post) on the Magnum PM-FST to 
 
the Receive (RX) port of  the remote device.  Begin with the color-coded strand 
 
of the cable for this first TX-to-RX connection. 
4.  Connect the Receive (RX) port (dark colored post) on the PM-FST to the (TX)
 
Transmit port of the remote device. Use the non-color coded fiber strand  for this. 
5.  The LINK LED on the front of the PM-FST will illuminate when a proper 
 
connection has been established at both ends (and when power is ON in the 
 
unit).  If LINK is not lit after cable connection, the normal cause is improper 
 
cable polarity.  Swap the fiber cables at the Port Module connector to remedy 
 this 
situation. 
 
3.1.6 
Connecting Fiber Optic (SC-type, "Snap-On") 
 
The same five-step procedure as for fiber ST-type applies to FOIRL and 
10BASE-FL applications using an RPM-SC card used with SC-type fiber connectors.  
Follow the five steps as described in the Section 3.3.5 above. 
 
When connecting fiber media to SC connectors, simply snap on the square 
male connector into the SC female jack of the device until it clicks and secures. 
 
3.1.7 
Connecting Single-Mode Fiber Optic (SMF) 
 
When using the RPM-SMF, be sure to use single-mode (small diameter) fiber 
cable. The same five-step procedure as for multi-mode ST-type applies to single-mode. 
 
3.1.8 
Power Budget Calculations for Magnum 3000s RPM’s with Fiber 
Media 
 
 
Receiver Sensitivity and Transmitter Power are the parameters necessary to 
compute the power budget. To calculate the power budget of different fiber media 
installations using Magnum products, the following equations should be used: 
OPB (Optical Power Budget) = P
T
(min) - P
R
(min) 
      
 where P
= Transmitter Output Power, and P
R
 = Receiver Sensitivity 
 
   Worst case OPB = OPB - 1dB(for LED aging) - 1dB(for insertion loss) 
   Worst case distance = {Worst case OPB, in dB} / [Cable Loss, in dB/Km] 
 
where the “Cable Loss” for 62.5/125 and 50/125
µm