Q-Logic 16HA Manual De Usuario
Preliminar
y
SANbox-16HA Fibre Channel Switch Specifications
SANbox-16HA Fibre Channel Switch
A-4
Reference Information
59005-03 Rev. A
Installer’s/User’s Manual
Switch Maintainability
Maintenance Strategy: .......................FRU-based:
GBIC Modules
Power supplies/fans
AC input fuses
Power supplies/fans
AC input fuses
Does not require enclosure opening for any
reason, including:
reason, including:
GBIC insertion to populate/activate
new ports
GBIC replacement
Redundant power supply replacement
new ports
GBIC replacement
Redundant power supply replacement
Does not require system interruption for:
GBIC insertion to populate/activate
new ports
GBIC replacement
Redundant power supply replacement
new ports
GBIC replacement
Redundant power supply replacement
Backup Components: .........................Hot-swappable spare power supply and
integral cooling fan. Redundant Power
Cables and Input Fuses)
Cables and Input Fuses)
Diagnostics:........................................Power-On-Self-Test (POST) tests all
functionality except media modules.
Field selectable Continuous Test tests all
functionality including media modules.
Field selectable Continuous Test tests all
functionality including media modules.
Fabric Management
Fabric Management:...........................Simple Name Server, Alias Server, SNMP,
the SANsurfer Web-based Java application,
and Telnet
and Telnet
User Interface:....................................LED indicators
Maintenance Interface: ......................Ethernet 10/100 BASE-TEthernet
Connector:..........................................RJ-45
Connector:..........................................RJ-45