C
ONFIGURING
 
THE
 S
WITCH
3-140
-Default:
- Ethernet – Half duplex: 2,000,000; full duplex: 1,000,000; 
  trunk: 500,000
- Fast Ethernet – Half duplex: 200,000; full duplex: 100,000; 
  trunk: 50,000
- Gigabit Ethernet – Full duplex: 10,000; trunk: 5,000
Admin Link Type – The link type attached to this interface.
- Point-to-Point – A connection to exactly one other bridge.
- Shared – A connection to two or more bridges.
- Auto – The switch automatically determines if the interface is 
attached to a point-to-point link or to shared media. (This is the 
default setting)
Admin Edge Port (Fast Forwarding) – You can enable this option if 
an interface is attached to a LAN segment that is at the end of a bridged 
LAN or to an end node. Since end nodes cannot cause forwarding 
loops, they can pass directly through to the spanning tree forwarding 
state. Specifying Edge Ports provides quicker convergence for devices 
such as workstations or servers, retains the current forwarding 
database to reduce the amount of frame flooding required to rebuild 
address tables during reconfiguration events, does not cause the 
spanning tree to initiate reconfiguration when the interface changes 
state, and also overcomes other STA-related timeout problems. 
However, remember that Edge Port should only be enabled for ports 
connected to an end-node device. (Default: Disabled)
Migration – If at any time the switch detects STP BPDUs, including 
Configuration or Topology Change Notification BPDUs, it will 
automatically set the selected interface to forced STP-compatible 
mode. However, you can also use the Protocol Migration button to 
manually re-check the appropriate BPDU format (RSTP or 
STP-compatible) to send on the selected interfaces. 
(Default: Disabled)