Cisco Systems Intelligent Gigabit Ethernet Switch Module Manual De Usuario

Descargar
Página de 62
 
Chapter 2. Message and Recovery Procedures
 25
PLATFORM_CAT2950-3-REG_READ_FAILURE: Register read failed for [chars] in [chars]
Explanation This message means that the register read failed for register [chars] in [chars]. An attempt 
to read a valid location in the internal chip register failed. This could be due to a hardware defect. 
Response
Find out more about the error by using the show tech-support privileged EXEC command and 
by copying the error message exactly as it appears on the console or system log and entering it in the Output 
Interpreter tool. Use the Bug Toolkit to look for similar reported problems. For more information about these 
online tools , see the 
PLATFORM_CAT2950-3-REG_WRITE_FAILURE: Register write failed for register [chars] in [chars]
Explanation This message means that an attempt to write to a location in the internal chip register 
failed. This might be caused by writing to an invalid register location or by a defect in the hardware.
Response
Find out more about the error by using the show tech-support privileged EXEC command and 
by copying the error message exactly as it appears on the console or system log and entering it in the Output 
Interpreter tool. Use the Bug Toolkit to look for similar reported problems. For more information about these 
online tools , see the 
PLATFORM_CAT2950-3-PCI_TEST_FAILURE: PCI address space test failed, Wrote [hex], read [hex], re-read [hex].
Explanation This message means that, during POST, the PCI address space for the ASIC was not 
mapped correctly. This might occur because of a system PCI-bus problem. The first [hex], the second 
[hex], and the third [hex] are test data.
Response
Find out more about the error by using the show tech-support privileged EXEC command and 
by copying the error message exactly as it appears on the console or system log and entering it in the Output 
Interpreter tool. Use the Bug Toolkit to look for similar reported problems. For more information about these 
online tools , see the 
PLATFORM_CAT2950-3-SCHAN_OP_FAILURE: S-channel operation timeout for opcode [chars].
Explanation This message means that there was a failure to read or write to an ASIC register or a 
memory location because of an ASIC internal bus failure. [chars] is the operation code.
Response
If the message recurs, find out more about the error by using the show tech-support privileged 
EXEC command and by copying the error message exactly as it appears on the console or system log and 
entering it in the Output Interpreter tool. Use the Bug Toolkit to look for similar reported problems. For more 
information about these online tools , see the 
.
PLATFORM_CAT2950-3-SCHAN_READ_REG_FAILURE: S-channel operation read register failure at addr [hex].
Explanation This message means that there was a failure to read the ASIC registers, which might occur 
because of an invalid register address or internal bus failure. [hex] is the register address.
Response
If the message recurs, find out more about the error by using the show tech-support privileged 
EXEC command and by copying the error message exactly as it appears on the console or system log and 
entering it in the Output Interpreter tool. Use the Bug Toolkit to look for similar reported problems. For more 
information about these online tools , see the 
.