Philips BUK205-50Y Manual De Usuario

Descargar
Página de 13
Philips Semiconductors
Product specification
 TOPFET high side switch
BUK205-50Y 
 SMD version of BUK201-50Y
 
Fig.22.   Typical status clamping voltage, V
SG
 = f(T
j
).
parameter V
IG
; conditions I
S
 = 100 
µ
A, V
BG
 = 13 V
Fig.23.   Low load current detection threshold.
I
L(OC)
 = f(T
j
); conditions V
IG
 = 5 V; V
BG
 = 13 V
Fig.24.   Supply typical undervoltage thresholds.
V
BG(TO)
 = f(T
j
); conditions V
IG
 = 3 V; I
L
 = 80 mA
Fig.25.   Supply typical overvoltage thresholds.
V
BG(LP)
 = f(T
j
); conditions V
IG
 = 5 V; I
L
 = 80 mA
Fig.26.   Typical battery to ground clamping voltage.
V
BG
 = f(T
j
); parameter I
G
Fig.27.   Typical negative load clamping characteristic.
I
L
 = f(V
LG
); conditions V
IG
 = 0 V, t
p
 = 300 
µ
s, 25 ˚C
-60
-20
20
60
100
140
180
Tj / C
VSG / V
BUK205-50Y
8.0 
7.5 
7.0 
6.5 
5
VIG / V =
0
-60
-20
20
60
100
140
180
Tj / C
VBG(LP) / V
BUK205-50Y
47 
46 
45 
44 
43 
on
off
-50
0
50
100
150
200
0
100 
200 
300 
400 
500 
600 
700 
800 
BUK205-50Y
Tmb / C
IL(OC) / mA
max.
min.
typ.
-60
-20
20
60
100
140
180
Tj / C
VBG / V
BUK205-50Y
65 
60 
55 
50 
10 uA
1 mA
IG =
-60
-20
20
60
100
140
180
Tj / C
VBG(TO) / V
BUK205-50Y
on
off
-25
-20
-15
-10
-5
0
0
5
10
15
20
25
30
BUK205-50Y
VLG / V
IL / A
July 1996
9