Cisco Systems SFS 7000D Manual De Usuario

Descargar
Página de 80
 
5-7
Cisco SFS 7000P and SFS 7000D InfiniBand Server Switches Hardware Installation Guide
OL-10853-01
Chapter 5      Managing the Switch
Displaying System Information
Displaying Fan Information
To display information about the fans, enter the show fan command.
An oper-status of up means that the fan is operating correctly within the power supply module. 
In the Speed field, the integer represents a percentage. The percentage changes based on the ambient 
temperature of the unit and increases as the temperature rises. 
SFS-7000P# show fan
================================================================================
                                Fan Information
================================================================================
fan   oper-status   speed(%)
--------------------------------------------------------------------------------
1     up            73
2     up            73
3     up            73
4     up            73
================================================================================
                                  Fan Seeprom
================================================================================
      product              pca                pca                fru
 
fan   serial-number        serial-number      number             number
 
--------------------------------------------------------------------------------
1
 
2
 
3
 
4
Displaying Sensor Information
To display information about the sensors, enter the show sensor command.
SFS-7000P# show sensor
================================================================================
                               Sensor Information
================================================================================
sensor oper-status oper-code  temperature(c)  alarm-temp(c)   shutdown-temp(c)
--------------------------------------------------------------------------------
1/1    up          normal     29              65              73
The temperature fields show temperatures in Celsius. The Current Temp field shows the current internal 
temperature. The Alarm Temp field shows the temperature at which the system goes above its internal 
temperature limit. The Shutdown Temp field shows the temperature at which the system power cycles. 
For operating and non-operating temperatures, see