Cisco Systems SFS 7000D Manual De Usuario
6-4
Cisco SFS 7000P and SFS 7000D InfiniBand Server Switches Hardware Installation Guide
OL-10853-01
Chapter 6 Hardware Diagnostic Tests
About Diagnostic Tests
Step 3
Display any errors on individual components by entering the show diag post command.
SFS-7000P-1# show diag post
======================================================================
Post Status
======================================================================
fru-slot post-status post-error
----------------------------------------------------------------------
card(1) failed _FRU_LIM_CARDTYPE_ERR
card(3) failed _FRU_SEEPROM_PROGRAM_ERR
card(5) passed none
card(6) passed none
card(7) passed none
card(8) passed none
card(9) passed none
card(11) failed _FRU_POWER_CONTROLLER_CONFIG_ERR
card(12) passed none
card(13) passed none
card(15) passed none
card(16) passed none
card(17) passed none
fan(1) passed none
Running Fan Self-Test
The procedures in this section describe the fan module tests and provide sample text from performing a
fan test.
fan test.
Note
The sample text in the steps below shows command output for the Cisco SFS 7000P Server Switch. For
the Cisco SFS 7000D Server Switch, you would see a similar display.
the Cisco SFS 7000D Server Switch, you would see a similar display.
To perform a diagnostic self-test on a fan, follow these steps:
Step 1
Identify the number of the fan you want to diagnose, if you do not already know the number. Power
supply 1 contains fan number 1, and power supply 2 contains fan number 2. (See
supply 1 contains fan number 1, and power supply 2 contains fan number 2. (See