Cisco Systems SFS 7000D Manual De Usuario

Descargar
Página de 80
 
6-4
Cisco SFS 7000P and SFS 7000D InfiniBand Server Switches Hardware Installation Guide
OL-10853-01
Chapter 6      Hardware Diagnostic Tests
About Diagnostic Tests
Step 3
Display any errors on individual components by entering the show diag post command.
SFS-7000P-1# show diag post
======================================================================
                                  Post Status
======================================================================
fru-slot        post-status     post-error
----------------------------------------------------------------------
card(1)         failed          _FRU_LIM_CARDTYPE_ERR
card(3)         failed          _FRU_SEEPROM_PROGRAM_ERR
card(5)         passed          none
card(6)         passed          none
card(7)         passed          none
card(8)         passed          none
card(9)         passed          none
card(11)        failed          _FRU_POWER_CONTROLLER_CONFIG_ERR
card(12)        passed          none
card(13)        passed          none
card(15)        passed          none
card(16)        passed          none
card(17)        passed          none
fan(1)          passed          none
Running Fan Self-Test
The procedures in this section describe the fan module tests and provide sample text from performing a 
fan test.
Note
The sample text in the steps below shows command output for the Cisco SFS 7000P Server Switch. For 
the Cisco SFS 7000D Server Switch, you would see a similar display.
To perform a diagnostic self-test on a fan, follow these steps:
Step 1
Identify the number of the fan you want to diagnose, if you do not already know the number. Power 
supply 1 contains fan number 1, and power supply 2 contains fan number 2. (See