Double-conversion design 
offers the highest protection 
possible
Unlike some other commercially 
available UPS technologies, 
the double-conversion design 
completely isolates output 
power from all input power 
anomalies and delivers 100-
percent conditioned, perfect 
sine-wave output—regulating 
both voltage and frequency. 
Even when presented with the 
most severe power problems, 
power output remains stable. 
Output voltage THD is held 
within two percent of nominal 
specification for linear loads, 
within five percent for non-
linear loads—making the 
Powerware 9395 ideal for 
supporting equipment that is 
sensitive to a distorted voltage 
input as a result of harmonic 
loads. In the event of a utility 
power failure, there is no delay 
transferring to backup power. 
Scalable, upgradeable  
architecture meets your current 
and future load requirements
The Powerware 9395 is 
designed to be field-upgrade-
able for capacity or redun-
dancy. For example, a 275 kVA 
system can be upgraded on-site 
to 550 kVA or to an N+1 275 
kVA redundant system. In an 
age where data center loads 
change quickly, this flexible 
design allows you to buy what 
you need now and upgrade or 
reconfigure later.
Flexible, pre-wired installation 
options expedite deployment 
and save valuable space
The Powerware 9395 UPS 
offers the smallest footprint 
and lowest weight of any UPS 
in its class—50 to 60 percent 
less than competitive units. 
Cabling can enter the UPS 
from either the top or bottom 
of the cabinet to provide easier 
and flexible installation. Multi-
module systems arrive pre-
wired in an integrated system 
so there’s no need to perform 
all of the inter-unit cabling for 
power and communications 
between modules and the 
system bypass unit. As a result, 
you save time and money.
Service design maximizes 
uptime
Our new concurrent service 
feature allows the Powerware 
9395 to be serviced while one 
of the redundant modules 
carries the load. Because the 
redundant module provides 
uninterrupted and protected 
power to your load during 
service, there is no need 
to put your critical load on 
utility bypass while a power 
module is being serviced. The 
Powerware 9395 maximizes the 
availability of your electrical 
power.
The Powerware 9395 provides 
front panel access for all 
services and operation, 
increasing serviceability and 
reducing Mean Time to Repair 
(MTTR). And since the compact 
Powerware 9395 cabinet can 
be installed against back and 
side walls, you have more 
location options, installation is 
fast and easy, deployment cost 
is lower, and you save valuable 
data center space for future 
expansion. 
UPS control innovations 
optimize battery performance 
and service life
Eaton’s ABM
®
 (Advanced 
Battery Management) 
technology uses a unique three-
stage charging technique that 
significantly extends battery 
service life and optimizes 
recharge time, compared to 
traditional trickle charging. An 
integrated battery management 
system tests and monitors 
battery health and remaining 
lifetime, and provides advance 
notification to guide preventive 
maintenance. Optional 
temperature-compensated 
charging monitors temperature 
changes and adjusts the charge 
rate accordingly to properly 
charge the battery and greatly 
extend battery life.  With our 
Powerware 9395 UPS with redundant, field-installed module 
275 kVA field-upgradable 
UPM can be added for 
redundancy or capacity
550 kVA Integrated 
system bypass 
module (ISBM)
Redundant 275 kVA 
uninterruptible power 
modules (UPM)