AMT Datasouth 4500 Series Manual De Usuario

Descargar
Página de 94
Data Communications
20
Serial Port Specifications
Table 3 lists the RS-232 signals supported by the printer.
Pin #
Signal Description
Signal
Mnemonic
Direction
1
Shield
--
--
2
Received Data
RXD
Input to the printer
3
Transmitted Data
TXD
Output from the printer
4
Clear to Send
CTS
Input to the printer
5
Request to Send
RTS
Output from the printer
6
Data Terminal Ready
DTR
Output from the printer
7
Signal Ground
GND
--
20
Data Set Ready
DSR
Input to the printer
22
 Ring Indicator
RI
Output from the printer
Table 3 - CodeWriter 4500 Series RS-232 Signals
Cable Examples
Connecting to DTE (Data Terminal Equipment) host systems with a DB25
connector requires a cable with pin-to-pin wiring and a male DB25 for the
printer (Figure 7). Connecting to a DCE (Data Circuit-terminating Equipment)
device, such as a modem, will require a “NULL-MODEM” style circuit with
appropriate connectors on each end (Figure 8).
Figure 7 – 4500 Series Printer to DTE Host System Cable Diagram
Shield    1
RXD    2
TXD    3
CTS    4
RTS    5
DTR    6
GND    7
DSR  20
RI  22
1   Shield
2   TXD
3   RXD
4   RTS
5   CTS
6   DSR
7   GND
20 DTR
22 RI
DTE Host
DB25 Connector
4500 Series Printer
DB25 Connector