Chapter 5: Programming commands
142
A776 (B780) Programming Guide 
A776-PG00001 C 12/09
If the image file return port is RS232, then the header and attached image file are transmitted under the settings of the 
Configure RS232 File Transmit parameters.
XON-XOFF will not work for transmission of image.
Eject from Scanner
Hexadecimal:  1D BA p
Parameters:  p specifies the action: 0 = eject from entry point, 1 = eject front, 2 = eject straight back, 3 = move down 
into slip print position
Return:   Status is returned as follows using the standard status return:
Value
Definition
1D
Command return indicator
49
Image Scanner
BA
Imaging function = eject
s
Standard imaging status as described above in section 8.2.1
s
Standard imaging status
Decimal
Meaning
0
OK
1
Jam detected
2
Wait for scan document cancelled
3
Imager cover open
7
Unrecoverable hardware error
8
No stored document
9
Bottom side only
10
Top side only
11
Internal interface timeout error
12
Internal interface other error
16
No bottom image
17
No top image
18
Unsupported format
19
Tag block full
m
m as in the Image Status Command return
n
n as in the Image Status Command return
pL pH
p as in the Image Status Command return
rL rH
r as in the Image Status Command return
Description: This command ejects the document or moves it into the slip printer for further processing. A request for 
moving a top inserted document down into slip print position will instead eject it out the back.