Xerox 6115 Prospecto

Descargar
Página de 2
Installation Preparation Document 
(for physical installation of the product only)
 
 
Xerox DocuTech 6100/6115/6135
 
 
 
701P43857 
June 2005
 
Please ensure electrical, space, and supplies are available prior to equipment delivery.
 
 
Physical requirements  
• 
The DocuSP Controller Monitor and Keyboard are designed to 
be positioned on top of the DocuTech 61XX printer. The 
controller platform is designed to either be mounted in a stand to 
the left of the printer, or to be positioned on the floor to the left of 
the printer. 
 
• 
Warning: Due to safety requirements, under no circumstances 
should the user interface be visually separated from the printer 
module. All system installations must enable mobility of the user 
interface to within 30” (760 mm) of the printer for service and 
customer maintenance actions
.
 
 
 
Environmental Requirements
 
 Min. 
Max. 
Temperature  
50 
o
 F 
85 
o
 F * 
Humidity 
30% RH 
60%  RH 
Heat Emission - with 
Binder On 
22,165 
BTU/Hr 
14,185  BTU/Hr 
(With Vent Kits) 
Heat Emission - with 
Binder Off 
21,265 
BTU/Hr 
13,609  BTU/Hr 
(With Vent Kits) 
Power Consumption 
Printer/Finisher w/ Binder 
On 
1,330 Watts 
(Standby) 
5,890  Watts 
(Running) 
Power Consumption 
Printer/Finisher w/Binder 
Off 
1,000 Watts 
(Standby) 
5,630  Watts 
(Running) 
* The system will inhibit software problems and shut down above 90 
o
 
Operating Supplies
 
 
Reorder No. 
Impressions / Unit 
Dry Ink  
6R206 
220K/Carton at 6% 
area coverage 
Developer 
5R161 
750K / Carton 
Fuser Agent 
8R2955 
250K / Bottle 
Stitcher Wire 
8R1174 
32K / Roll 
Binder Tape - Black 
8R2928 
425 Binds / Reel 
Binder Tape – White 
8R3601 
425 Binds / Reel 
Binder Tape – Gray 
8R3602 
425 Binds / Reel 
Binder Tape – Blue 
8R3603 
425 Binds / Reel 
Binder Tape – Brown 
8R3604 
425 Binds / Reel 
Binder Tape – Red 
8R3824 
425 Binds / Reel 
The Xerox Supplies Marketing Center, 1.800.822.2200, is available 
for ordering Xerox supplies, including paper and other thruput 
material. 
 
Network Requirements
 
• 
The Ethernet interface on the DocuSP controller is a 10/100-
MB/sec twisted pair standard (10BaseT).   
 
• 
The Ethernet connection to the DocuSP controller must be 
compatible with the Institute of Electrical and Electronics 
Engineers (IEEE) 802.3 standard.  (The physical form of this 
connecter is RJ45 and must be correctly wired.) 
• 
The DocuSP controller supports TCP-IP, SPX,/IPX, and 
EtherTalk Link Access Protocol (ELAP) protocols if the proper 
gateways are installed on the controller. 
• 
The DocuSP controller does not provide Novell Server network 
services.  To use the SPX/IPX protocol, a Novell server installed 
on the network is required. 
• 
A Xerox Token Ring solution is available for the 61XX family. 
When Token Ring is installed, it becomes a Token Ring only 
connectivity solution. The NetWare gateway and AppleTalk 
gateway will not function, and the built in Ethernet bge0 twisted 
pair interfaces are disabled.  (Gigabit Ethernet is supported with 
a Sun controller card – some customers have asked for this 
option.) 
 
Telephone Requirements
 
A voice telephone line is required where the DocuTech 6100, 6115, 
6135, is installed.  
Voice line will be used when the operator, administrator, or Xerox 
Service Personnel is asked to read the screen information from the 
DocuSP controller dialogs to Xerox Customer Support or Technical 
Support Center Personnel. 
 
 
Position / Performance at Maturity 
Average
Monthly
Service
Calls
8
7
6
5
4
3
2
1
Average Monthly Copy Volume
300K
1M
2M
Optimum Range
500K
1.5M
 
Note:   
This product is targeted for the 300K to 2M copies per month market 
segment.  Usage above this range may result in a higher service 
frequency