Cisco Systems AIRONET 1000 Manual De Usuario

Descargar
Página de 83
 
2-19
Cisco Aironet 1000 Series Lightweight Access Point Hardware Installation Guide
OL-9403-04
Chapter 2      Installing the Access Point
Powering Up the Access Point
Connecting to an Ethernet Network with Local Power
Note
If your access point is connected to in-line power, do not connect the power module to the access point. 
Follow these steps to connect the access point to an Ethernet LAN when you are using a local power 
source:
Step 1
Connect a Category 5 Ethernet cable to the RJ-45 Ethernet connector labeled Ethernet on the access 
point (see 
). 
Step 2
Plug the other end of the Ethernet cable into an non-powered Ethernet port on your 10/100 Ethernet 
LAN.
Step 3
Connect the power module output connector to the access point’s 48-VDC power port (see 
Step 4
Plug the power module power cord into an approved 100- to 240-VAC outlet.
Powering Up the Access Point 
After you power up the access point, it begins a power-up sequence that you can check by observing the 
access point LEDs. The red Alarm LED turns on for about 15 to 20 seconds and then all LEDs blink 
sequentially back and forth, indicating that the access point is trying to find a controller. Refer to 
 for LED descriptions.
After the access point finds the controller, the access point downloads new operating system code if the 
access point code version differs from the controller code version. During the download process, all 
access point LEDs blink simultaneously. When the operating system download is successful, the access 
point reboots. 
Normal operation is indicated when the Alarm LED is off, the Power LED is green, and the 2.4 GHz and 
5 GHz LEDs are blinking to indicate radio activity.
If no LEDs are on, the access point might not be receiving sufficient power.
If all the LEDs blink sequentially for more than five minutes, the access point is unable to find its 
primary, secondary, or tertiary controllers. Check the connection between the access point and its 
controllers and ensure they are on the same subnet or that the access point has a route back to its primary, 
secondary, and tertiary controllers. If the access point is not on the same subnet as the controllers, ensure 
there is a properly configured DHCP server on the same subnet as the access point. See the 
 for DHCP information.
Note
To allow client roaming between access points, the access points must be on the same subnet. 
Note
Connect only one power source to the access point, for example: When using in-line power, do not 
connect the power module to the access point.