3-5
Cisco Aironet 1000 Series Lightweight Access Point Hardware Installation Guide
OL-9403-04
Chapter 3      Troubleshooting
Low Power Condition
Low Power Condition
Warning
This product must be connected to a Power over Ethernet (PoE) IEEE 802.3af compliant power source 
or an IEC60950 compliant limited power source. 
Statement 353
The access point can be powered from the 48-VDC power module or from an in-line power source. The 
access point supports the IEEE 802.3af power standard for in-line power sources. 
For operation, the access point (powered device) requires 12 W of input power. 
Note
When the access point is being used in a PoE configuration, the power drawn from the power sourcing 
equipment (PSE), such as a switch or power injector, is higher by an amount dependent on the length of 
the interconnecting cable.
The power module (AIR-PWR-1000=) and the Cisco Aironet power injector (AIR-PWRINJ-1000af=) 
are capable of supplying the required operating power, but some inline power sources are not capable of 
supplying sufficient power. Also, some high-power inline power sources, might not be able to provide 
sufficient power to all ports at the same time.
Note
An 802.3af compliant switch (Cisco or non-Cisco) is capable of supplying sufficient power for full 
operation.
Note
If your access point is connected to in-line power, do not connect the power module to the access point. 
On power up, the access point is placed into low power mode (both radios are deactivated), the access 
point power negotiation determines if sufficient power is available. If there is sufficient power then the 
access point begins to power up (Alarm LED is red and other LEDs are off); otherwise, the access point 
turns off all LEDs and remains in low power mode to prevent a possible over-current condition.