ZyXEL Communications P-312 Manual De Usuario

Descargar
Página de 254
P312  Broadband Security Gateway
Filters
7-13
The following table describes the fields in the Generic Filter Rule Menu.
Table 7-5 
Generic Filter Rule Menu Fields
Field
Description
Option
Filter #
This is the filter set, filter rule co-ordinates, i.e., 2,3 refers to the second
filter set and the third rule of that set.
Filter Type
Use the [SPACE BAR] to toggle between both types of rules. Parameters
displayed below each type will be different.
Generic Filter
Rule/
 TCP/IP
Filter Rule
Active
Select Yes to turn on the filter rule.
Yes/No
Offset
Enter the starting byte of the data portion in the packet that you wish to
compare. The range for this field is from 0 to 255.
Default = 0
Length
Enter the byte count of the data portion in the packet that you wish to
compare.  The range for this field is 0 to 8.
Default = 0
Mask
Enter the mask (in Hexadecimal) to apply to the data portion before
comparison.
Value
Enter the value (in Hexadecimal) to compare with the data portion.
More
If yes, a matching packet is passed to the next filter rule before an action is
taken; else the packet is disposed of according to the action fields.
If More is Yes, then Action Matched and Action Not Matched will be No.
Yes / No
Log
Select the logging option from the following:
None – No packets will be logged.
Action Matched - Only packets that match the rule parameters will
be logged.
Action Not Matched - Only packets that do not match the rule
parameters will be logged.
Both – All packets will be logged.
None
Action
Matched
Action Not
Matched
Both
Action
Matched
Select the action for a matching packet.
Check Next
Rule
Forward
Drop
Action Not
Matched
Select the action for a packet not matching the rule.
Check Next
Rule
Forward