ZyXEL Communications P-312 Manual De Usuario

Descargar
Página de 254
P312  Broadband Security Gateway
11-4
System Maintenance & Information
Table 11-2 
Call History Fields
Field
Description
Phone Number
The PPPoE service names are shown here.
Dir
This shows whether the call was incoming or outgoing.
Rate
This is the transfer rate of the call.
#call
This is the number of calls made to or received from that telephone
number.
Max
This is the length of time of the longest telephone call.
Min
This is the length of time of the shortest telephone call.
Total
This is the total length of time of all the telephone calls to/from that
telephone number.
11.3  Time and Date Setting
There is no Real Time Chip (RTC) chip in the Prestige, so we have a software mechanism to get the current
time and date from an external server when you power up your Prestige. Menu 24.10 does just that – it
allows you to update the time and date settings of your Prestige. The real time is then displayed in the
Prestige error logs and firewall logs. If you do not choose a time service protocol that your timeserver will
send when the Prestige powers up you can enter the time manually but each time the system is booted, the
time & date will be reset to 2000/01/01 00:00:00.
11.3.1 How often does the Prestige update the time?
The Prestige updates the time in three instances:
i. 
On leaving Menu 24.10 after making changes.
ii. 
When the Prestige boots up and there is a time server configured in Menu 24.10.
iii. 
The time is also updated at 24-hour intervals after booting.