Cabletron Systems NB20E Manual De Usuario

Descargar
Página de 30
TESTING AND LANVIEW
4-2
5. Using a transceiver (5) and an AUI cable, connect another LAN-MD 
(4) to the other segment connected to the bridge.
6. Select and run test 4 - NODE on the LAN-MD connected in the 
previous step.
7. Verify that this test passes. At least 100 packets should be sent and 
received by the bridge, with no errors. Packets will be sent from this 
LAN-MD to the other LAN-MD, acting as the Server, then echoed 
back.
When the NB20E or NB25E have successfully completed these tests, the 
bridge is ready for normal operation. If any failures were noted, please 
contact Cabletron Systems' Technical Support.
4.2
USING LANVIEW
The NB20E and NB25E Two Port Ethernet Bridges use Cabletron 
Systems' built-in visual diagnostic and status monitoring system called 
LANVIEW. With LANVIEW, network troubleshooting personnel can 
quickly scan LANVIEW's LEDs to observe network status, or diagnose 
network problems. Figure 4-1 displays the LANVIEW LEDs on the 
NB20E and NB25E.
Figure 4-2
Check Out Configuration
3
2
4
1
5
Seg. A
Seg. B
1. ST-500
2. LAN-MD
3. NB 20E/25E
4. LAN-MD
5. ST-500 Transceiver