RAD Data comm Modular Access Device with Integrated Router Manual De Usuario
Chapter 5 Setup Menu
FCD-IPM Installation and Operation Manual
5-72
Interface Parameters Menu
Frame Relay DLCI Parameters
Table 5-25. Frame Relay DLCI Parameters
Parameters Possible
Values
Description
DLCI
16
to 991
Specifies the DLCI number
State
Enabled
Disabled
Specifies the DLCI state
CIR
The value of this parameter is
obtained from the Frame
Relay provider.
Specifies the maximum amount of data (in bits) which
the network guarantees to transfer during the
measurement interval (the measurement interval is
usually one second)
usually one second)
Excess
The value of this parameter
should be received from the
should be received from the
Frame Relay provider.
Specifies the maximum amount of uncommitted data
bits that the network will attempt to deliver during the
bits that the network will attempt to deliver during the
measurement interval
Throughput
Specifies the average number of data bits per second
transferred by the network. When a measurement
interval of one second is assigned to the CIR, the
throughput value should equal the CIR value.