3com 980-000077/002 Manual De Usuario
2-12
C
HAPTER
2: B
RIDGING
AND
IP
4 Press [Ctrl]+[E] to submit the new setting and then enter
SAVE
Configure the ISDN Autocall Table
Set up the ISDN Autocall table to associate the central site unit IP
address with its name.
address with its name.
1 Enter
CO
IS
AUTO
IP
to display the ISDN IP Autocall Addresses
screen.
2 Enter
ADD
to add an entry to the ISDN IP Autocall table.
3 Type the name of the central site unit in the Remote Unit field. Ensure
that the name is correctly typed because this field is case-sensitive.
Unit names are case-sensitive and must be entered correctly.
4 Type the IP address of the central site unit in the IP Address field.
5 Press [Ctrl]+[E] to submit the new setting and then enter
SAVE
Close the Remote Management Session
1 Enter
QUIT
to close the remote management session.
The Remote Units screen on the central site unit is displayed.
Cancel the Manual Call
It is important to remember that a manual call is still running from
the initial connection to the remote unit. The call must be cancelled
manually.
the initial connection to the remote unit. The call must be cancelled
manually.
1 Enter
CO
IS
NU
to display the ISDN Numbers screen.
2 Select the entry for the remote site unit and enter
CANC
to cancel the
call.
3 Enter
SAVE
to save the new configuration.
All manual calls must be cancelled when the unit configuration is
complete. A “call guillotine” operates after 60 minutes (the default
setting) to cancel the calls but during this time, additional,
unnecessary, call charges will have accrued.
complete. A “call guillotine” operates after 60 minutes (the default
setting) to cancel the calls but during this time, additional,
unnecessary, call charges will have accrued.
Get_con.bk : BRID_IP.FRM Page 12 Friday, October 3, 1997 1:49 PM