Bench Testing (Optional)  - Connect and Power Up 
Step 1: Connect the RJ45 at 
one end of a cable to the 
ODU. 
Step 2: Undo the retaining 
screw of the PIDU Plus and 
hinge back the cover
Step 4: Put the cover back 
and tighten the screw. 
Step 3: Plug in the ODU to 
PIDU Plus Cable ensuring 
that it snaps home. 
Step 5: Plug in power lead 
using a cable appropriate for 
the installation.  
Step 6: Connect a second 
Ethernet cable (shown in yel-
low) to the “LAN” socket of 
the PIDU Plus. 
Step 7: 30 seconds after powering, the Ethernet LED 
should be observed to flash slowly 10 times. If the Ethernet 
LED does not illuminate (Orange), then either the PIDU 
Plus or the cable to the ODU may be faulty. Replace cable 
and/or PIDU Plus and repeat from Step 1.
 
NOTE - If the power LED 
does not illuminate, re-
move the power cable 
and the ODU connection 
from the PIDU Plus. Re-
connect the power lead 
and check the power 
LED illumination (Green). 
If the power LED still 
does not light then check 
the power source.
 
Step 8: Ensure PC is set to 
correct IP address 169.254.1.x, 
where 2 < x < 254. Connect 
the LAN cable to the PC 
(shown here in yellow). 
Step 9: Check that the Ethernet 
LED is now ON.  Refer to the 
Troubleshooting section in this 
guide if the LED does not show 
any activity when accessing 
web pages. 
It is advised that the link be configured and tested on a bench before the final installation of the 
units on a pole or a mast. The following steps give details of how to connect an ODU to a PC in 
order to check the configuration details, change the IP settings or modify the license key. For 
the purpose of these tests, normal off-the-shelf Ethernet cables can be used.