Renesas 70 Manual De Usuario

Descargar
Página de 162
Chapter 6 Using Configurator 
   
- 115 - 
7. Extended 
information 
[( Definition format )] Numeric 
value 
[( Definition range )] 
1 to 0xFFFFFFFF 
[( Default value )]   0 
Define the extended information of the cyclic handler. This information is passed as argument to the 
cyclic handler when it starts. 
 
[( Alarm handler definition )] 
This definition is necessary to use Alarm handler function. 
<< Format >> 
 
 
 // Alarm Handlar Definition  
 alarm_hand[ 
 ID No. 
 ]{ 
  
name 
 
 ID name
 ;  
  
entry_address 
 Start address
 ;  
  
exitf 
 
 Extended information 
 ; 
 }; 
  
 
:  
  
 
 
The ID number must be in the range of 1 to 255. The ID number can be omitted. 
If omitted, numbers are automatically assigned sequentially beginning with the smallest. 
 
<< Content >> 
 
Define the following for each alarm handler ID number. 
1. ID 
name 
[( Definition format )] Symbol 
[( Definition range )] None 
[( Default value )]   None 
Define the name by which the alarm handler is specified in a program. 
2. Start 
address 
[( Definition format )] 
Symbol or Function Name 
[( Definition range )] None 
Define the start address of the alarm handler. The function name defined here causes the following 
declaration statement to be output in the kernel_id.h file. 
3. Extended 
information 
[( Definition format )] Numeric 
value 
[( Definition range )] 
1 to 0xFFFFFFFF 
[( Default value )]   0 
Define the extended information of the alarm handler. This information is passed as argument to the 
alarm handler when it starts.